    a bl e of C on t e n t s a bl e of C on t e n t s INTRODUCTION ......3 P ACKAGE CONTENTS .
  • Page 3: Introduction

    . NA13CT saf ety mo dule. It must be NA13CT mo dule do es no t sto red in a dry c lean p lac e c lo se to...
  • Page 4: Installation

    Fig. 1 - NA13CT diagram INSTALLATION electrical board clean place (minimum protection Warning degree: IP54), fixed on the spe- • The NA1/3-C-T safety module cial DIN rail. must installed following • If the safety module is tampered, standards in force in the country...
  • Page 5: Wiring

    E-STOP device(s). ered, the E-STOP is not pushed, E- STOP c o nne c t io n and the START circuit has been The NA13CT safety module can activated, described this be connected to one or more sin- user manual.
  • Page 6: Test & Activ Ation

    E-STOP button pushed. devices connected inputs and to the outputs of the NA13CT If more than one E-STOP is used, safety module. Check also the cor- STEPS must rect wiring of all the devices (See repeated for each device.
  • Page 7: Inspections And Maintenance

    (maximum delay allowed must be checked regularly accord- range) designing risk evaluation machine, in order to avoid the pos- machine, under complete sibility operator reach Fig. 2: NA13CT application with one single-channel E-STOP device...
  • Page 8: Applications

    Fig. 3: NA13CT application with one double-channel E-STOP device responsibility of the user. pushed, safety module switched off: safety outputs Regular inspections must be per- open and the auxiliary output clos- formed repeating all the operations es as soon as the releasing delay listed in the TEST &...
  • Page 9 Fig. 4: NA13CT application with two double-channel E-STOP devices Fig. 5: NA13CT application with two single-channel E-STOP devices...
  • Page 10: Technical Data

    TECHNICAL DATA ELECTRICAL CHARACTERISTICS 18 Vac -15/+10% 50 ÷ 60Hz, Supply Voltage 24 Vdc -15/+10% Current Consumption 50 mA (@ 24Vdc, without load) Power Consumption Max. 2 VA Input 1 or 2 N.O. Voltage-free Safety Category (EN 954-1) E-STOP Category (EN 60204-1) Short-Circuit Protection Internal PTC SAF ETY OUTPUTS...
  • Page 11 LED WARNINGS ON : Module supplied POWER OFF : Module not supplied ON : Safety outputs closed CH1 & CH2 OFF : Safety outputs open MECHANICAL AND ENVIRONMENTAL CHARACTERISTICS PA 6.6 flammability class Housing VO-UL94 Fixing OMEGA - DIN EN 50022 Rail Protection degree of the module IP30 Minimum Protection degree of...
  • Page 12 CARLO GAVAZZI reserves the right to make improvements or changes without prior notice.