CARLO GAVAZZI Certus CM22D0A Instruction Manual

CARLO GAVAZZI Certus CM22D0A Instruction Manual

Safety module

Advertisement

Quick Links

Certus Multifunction
safety module
Instruction manual
Manuale d'istruzione
Betriebsanleitung
Manuel d'instructions
Manual de instrucciones
Brugervejledning
使用手册
Carlo Gavazzi Automation Via Milano 13, 20020 Lainate (Milano) Italy

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Certus CM22D0A and is the answer not in the manual?

Questions and answers

Summary of Contents for CARLO GAVAZZI Certus CM22D0A

  • Page 1 Certus Multifunction safety module Instruction manual Manuale d’istruzione Betriebsanleitung Manuel d’instructions Manual de instrucciones Brugervejledning 使用手册 Carlo Gavazzi Automation Via Milano 13, 20020 Lainate (Milano) Italy...
  • Page 3: Table Of Contents

    14.2 Blink code ......................26 14.3 Error code ......................26 15. Technical data ....................27 16. Dimensions ....................28 17. Inspection and maintenance ................29 18. EU/EC Declaration of conformity ..............30 Rev.01 | CERTUS Multifunction Safety Module | © 2017 | CARLO GAVAZZI Automation...
  • Page 4 It must be kept in good condition and in a clean location accessible to all operators. Service and warranty In the event of malfunction or requests for information please contact the CARLO GAVAZZI branch or distributor in your country. Rev.01 | CERTUS Multifunction Safety Module | © 2017 | CARLO GAVAZZI Automation...
  • Page 5: Introduction

    This means cost saving and fewer product codes to manage. All rights to this document are reserved by Carlo Gavazzi Automation S.p.A. Copies may be made for internal use only. Please do not hesitate to make any suggestions for improving this document.
  • Page 6: Safety

    The device must be installed/configured in accordance with the specific risk analysis of the application and all the applicable standards. Carlo Gavazzi is not responsible for these operations or for any risks in connection with them. Reference should be made to the manual and to the relative product and/or application standards to ensure correct use of any devices connected to the Certus module within the specific application.
  • Page 7: Features

    Note: The values for PL, SIL, Cat. are maximum values and may differ according to the chosen application and/or the chosen trigger elements Information: Safety functions were not evaluated by UL Rev.01 | CERTUS Multifunction Safety Module | © 2017 | CARLO GAVAZZI Automation...
  • Page 8: Function Block Diagram

    A blinkcode indicating the error condition is given on the LED CHANNEL. The LED POWER will also be blinking (see paragraph 14.2) Rev.01 | CERTUS Multifunction Safety Module | © 2017 | CARLO GAVAZZI Automation...
  • Page 9: Devices

    This CERTUS module is compliant with standards EN 81-20 and 81-50 Warning: EN 81-20 defines the technical requirements for lift construction. EN 81-50 provides the framework for design and testing of lift components Rev.01 | CERTUS Multifunction Safety Module | © 2017 | CARLO GAVAZZI Automation...
  • Page 10: Terminal Layout

    To avoid possible interference, keep the Dém. man. / auto. Sortie sécurité OSSD connecting conductors separate from the power conductors. Entrée TOR Mode opération Entrée TOR 24VCC (-) Rev.01 | CERTUS Multifunction Safety Module | © 2017 | CARLO GAVAZZI Automation...
  • Page 11: Wiring

    Do not exceed the electrical ratings. Rev.01 | CERTUS Multifunction Safety Module | © 2017 | CARLO GAVAZZI Automation...
  • Page 12: Function Description

    10.3 Delayed NO Outputs There are 2 NOs delayed Input sensors incl. Start active inactive Direct Outputs The behaviour is off-delayed and retriggerable Delayed Outputs T delay T delay Rev.01 | CERTUS Multifunction Safety Module | © 2017 | CARLO GAVAZZI Automation...
  • Page 13: Available Output Configuration (Cm22D0A Only)

    The Hex-switch must only be rotated clockwise. Any move in a counter-clock direction will leads to a fail-safe situation. The Default setting is “O” (3NO + 1NC) Rev.01 | CERTUS Multifunction Safety Module | © 2017 | CARLO GAVAZZI Automation...
  • Page 14: Output Configuration

    While power is OFF you can rotate in either direction. Attention: Full rotations in a clockwise direction can be made several times if the right position is passed. Rev.01 | CERTUS Multifunction Safety Module | © 2017 | CARLO GAVAZZI Automation...
  • Page 15: Operation Configuration

    (SC1, SC2, SC3, SC6). The same happens with the electrical ESPEs (SC4, SC5). Information: SC4 and SC5 will be recognized indipendently of the status of the ESPE. Rev.01 | CERTUS Multifunction Safety Module | © 2017 | CARLO GAVAZZI Automation...
  • Page 16: E-Stop / E-Gate 4 Wire

    In particular, if the original operating mode was Manual, check that the unit has been reconfigured in this mode. Information: Please note that on e-stop applications an automatic start is not possible. Rev.01 | CERTUS Multifunction Safety Module | © 2017 | CARLO GAVAZZI Automation...
  • Page 17: E-Stop / E-Gate 3 Wire

    In particular, if the original operating mode was Manual, check that the unit has been reconfigured in this mode. Information: Please note that on e-stop applications an automatic start is not possible. Rev.01 | CERTUS Multifunction Safety Module | © 2017 | CARLO GAVAZZI Automation...
  • Page 18: E-Stop / E-Gate 2 Wire

    Please note that on e-stop applications an automatic start is not possible. Information: With single-channel wiring the safety level of the machine/plant may be lower than the safety level of the unit. Rev.01 | CERTUS Multifunction Safety Module | © 2017 | CARLO GAVAZZI Automation...
  • Page 19: Espd / (Type 4 / Type 2) Two Channels

    Check correct functioning of the entire safety system (module + input device) following each re-installation. In particular, if the original operating mode was Manual, check that the unit has been reconfigured in this mode. Rev.01 | CERTUS Multifunction Safety Module | © 2017 | CARLO GAVAZZI Automation...
  • Page 20: Testable Espd (Type 2 / Type 4)

    With single-channel wiring the safety level of the machine/plant may be lower than the safety level of the unit. Attention: Press the START button for 2 seconds to runs a test of the safety light beams. Rev.01 | CERTUS Multifunction Safety Module | © 2017 | CARLO GAVAZZI Automation...
  • Page 21: Safety Mat

    Information: With single-channel wiring the safety level of the machine/plant may be lower than the safety level of the unit. Rev.01 | CERTUS Multifunction Safety Module | © 2017 | CARLO GAVAZZI Automation...
  • Page 22: Lift Application (Cl20D2A Only)

    K1 and K2 must be forcibly guided relays, their impulse strenght (surge voltage strenght) depend on the operating voltage of the safety chain (in accordance with EN 60664-1 overvoltage category III) Rev.01 | CERTUS Multifunction Safety Module | © 2017 | CARLO GAVAZZI Automation...
  • Page 23: Lift Levelling Example

    EN 81-50: 2014: Safety rules for the construction and installation of lifts. Part 50: design rules, calculations, examinations and tests of lift components. Rev.01 | CERTUS Multifunction Safety Module | © 2017 | CARLO GAVAZZI Automation...
  • Page 24: Start Behaviour

    (use as a trip device according to IEC 61496). Failure to comply with this rule may result in serious risks to people exposed. Rev.01 | CERTUS Multifunction Safety Module | © 2017 | CARLO GAVAZZI Automation...
  • Page 25: Operation

    (only delayed configurations) Triggers are activated; start is performed; the outputs are active (NCs HIGH; NOs LOW) Please see error code description in Error code Paragraph 14.2 Rev.01 | CERTUS Multifunction Safety Module | © 2017 | CARLO GAVAZZI Automation...
  • Page 26: Blink Code

    STATE_X_REC_S Error in configuration recognition (different results) STATE_X_COMPEEPROM Error: Hex switch does not match EEPROM STATE_X_ESPD Error in communication with ESPD type STATE_X_ESPD_S21S22 Error in S21-S22 bridge Rev.01 | CERTUS Multifunction Safety Module | © 2017 | CARLO GAVAZZI Automation...
  • Page 27: Technical Data

    DIN EN 81-20:2014-11 DIN EN 81-50:2015-02 MTTFd 2403 a 1268 a 1,89 E-09 3,58 E-09 DCavg ß 2,00 E-02 2,00 E-02 ß 1,00 E-02 1,00 E-02 MTTR Rev.01 | CERTUS Multifunction Safety Module | © 2017 | CARLO GAVAZZI Automation...
  • Page 28: Dimensions

    All the units which use a safety function must be considered when calculating the overall safety level. 16. Dimensions mm 44mm 49mm 63mm 18mm Rev.01 | CERTUS Multifunction Safety Module | © 2017 | CARLO GAVAZZI Automation...
  • Page 29: Inspection And Maintenance

    In the event of a switch-off of the module or of the machine it is necessary to perform a test in order to verify the integrity of the module and the external device system. Rev.01 | CERTUS Multifunction Safety Module | © 2017 | CARLO GAVAZZI Automation...
  • Page 30: Eu/Ec Declaration Of Conformity

    N. QA130463 cert. N. EA130475 of Machinery Directive, where appropriate. Rev.01 | CERTUS Multifunction Safety Module | © 2017 | CARLO GAVAZZI Automation...
  • Page 31 Rev.01 | CERTUS Multifunction Safety Module | © 2017 | CARLO GAVAZZI Automation...

This manual is also suitable for:

Certus cm40d0aCertus cm30d1aCertus cl20d2a

Table of Contents