ND12DCGxxx (where xxx changed after an activity is per- is the AC supply voltage). formed. The ND12DCG name, used in this PACKAGE CONTENTS manual, is referred to all the mod- Application els (DC and AC supply), if not dif- The safety relay ND12DCG can be ferently specified.
√ Any guarantee is void following shown in the connection diagrams opening of the housing or unau- of this user’s manual. thorized modifications. Function √ Avoid mechanical vibrations The unit is enabled to start when greater than 5 g / 33 Hz when the two switches S1 &...
Page 5
Feedback control loop PNP aux output (collector of a PNP transistor with emit- ter connected internally to VCC) 13-14 First safety output (NO) 23-24 Second safety output (NO) 31-32 Relay auxiliary output (NC) Fig. 2 - Functional circuit diagram of ND12DCG relay...
A2 terminals. Close the feedback control loop and the input circuit. Connect the NC Feedback con- tacts of the external contactors to the Y1-Y2 terminals. Fig. 3 - DIN-Rail mounting Connect the two-hand control Fig. 4 - ND12DCG Connection diagram...
34 is available the collector of supply. the PNP transistor. Connect to the 34 terminal an WARNING external resistive load with R≥2400 √ Please, note the maximum Ohm (see fig. 3). length of the cables! Fig. 6 - Change of the ND12DCG safety relay...
Only one or no LED illuminates External wiring or internal fault is present. Check the external wiring and restart the safety relay. If the fault is still present, contact Carlo Gavazzi.
TECHNICAL DATA CHARACTERISTICS 24 VDC (Elec.fuse protect) Power supply voltage (Uv) or AC supply (110 VAC or 230 VAC) Voltage range 0.85 ... 1.1 Uv Frequency (AC Type) 50 - 60 Hz Power Consumption (Approx.) 2 VA / 2 W Safety Category 4 (EN13849 -1 : 2008) Safety parameters...
Page 10
CONTACTS DATA VALUES Mechanical lifetime cycles Electrical lifetime cycles (2A, 24 VDC) Pollution degree: 2. Creeping distance and clearance Basis insulation: Overvoltage (DIN VDE 0160) Category: 3/250 V (DIN VDE 0110) Protective Separation: Ov. Cat. 2 Contact security 6 A fast or 4 A slow (DIN VDE 0660 - Part 200) Voltage at S11 terminal 24 VDC...
Page 12
CARLO GAVAZZI reserves the right to make improvements or changes without prior notice.
Need help?
Do you have a question about the ND12DCG and is the answer not in the manual?
Questions and answers