The direct insertion type zirconia oxygen analyzer detector
Hide thumbs Also See for ZFK8:
Table of Contents

Advertisement

Converter specification (ZKM)
Concentration value indication:
Digital indication in 4 digits
Contact output signal:
(1) Contact specification; 6 points, 1a 250V AC/3A or 30V DC/3A
(2) Contact function;
Note1) The following Instrument errors (1) Thermocou-
ples break (2) Sensor break (3) Temperature fault
(4) Calibration fault (5) Zero/span adjustment fault
(6) Output error turn the contact-ON
Note2) Alarm selects just one as mentioned below (1)
High (2) Low (3) Upper and Lower (4) High-high
(5) Low-low, it turns ON while operating.
Note3) Under blow down is available in case of option,
and it turns ON while operating.
Contact input signal:
(1) Contact specification; 3points (the following option)
ON; 0V (10mA or less), OFF; 5V
(2) Contact function;
Calibration method:
(a) Manual calibration with key operation
(b) Auto. calibration (option)
Calibration cycle; 00 day 00 hour to
99 days 23 hours
(c) All calibration 
Calibration gas:
Zero gas; 0.010 to 25.00% O
Span gas: 0.010 to 50.00% O
tration
Zero gas; 0.25 to 2.0% O
Span gas; 20.6 to 21.0% O
(oxygen concentration in the air)
Blowdown:
A function for blowing out with com-
(option)
pressed air dust that has deposited in
the flow guide tube. Blowdown can be
performed for a predetermined time and
at predetermined intervals.
Blowdown cycle; 00 hour 00 minute to
Blowdown time; 0 minute 00 second
All manuals and user guides at all-guides.com
Output signal hold:
Valve and Flow meter (option):
Communication function:
Combustion efficiency display (option):
Operating temperature:
Operating humidity:
Storage temperature:
Storage humidity: 95% RH or less, non condensing
Construction:
Material:
Outer dimensions (H x W x D):
Mass {weight}:
2
Finish color:
2
2
Mounting method: Mounted flush on panel or on pipe
2
99 hours 59 minutes
to 0 minutes 999
seconds
Output signal is held during calibration,
processing recoverable sensor, process-
ing diagnosis of sensor, warm-up, PID
auto tuning, under set up maintenance
mode "available" and blowdown. The
hold function can also be released.
Selects zero or span gas during manual
zero or span calibration. Mounted on the
side of the converter.
RS485 (MODBUS) (option)
When you select this display, "rich mode
display" will be simultaneously displayed.
This function calculates and displays
combustion efficiency from oxygen
concentration and measured gas tem-
perature.
Thermocouple (R) is required for tem-
perature measurement.
−20 to +55ºC
95% RH or less, non condensing
−30 to +70ºC
Dust-proof, rainproof construction
(corresponding to IP66 or IP67 of IEC)
Aluminum case
170 X 159 X 70mm (IP66, Bench type)
220 X 230 X 95mm (IP67)
182 X 163.5 X 70.6mm (Bench type)
IP66: Approx. 2kg (excluding cable and
detector)
IP67: Approx. 4.5kg (excluding cable and
detector)
IP66: Case: Silver
Cover: Pantone Cool Gray 1C-F
IP67: Munsell 6PB 3.5/10.5 (blue)
Cover: Silver (case)