Ros HPS-1000/Q Operating And Maintenance Manual

Droplight system

Advertisement

Quick Links

DROPLIGHT SYSTEM
OPERATING AND MAINTENANCE MANUAL
SERIAL NUMBER:
SALES ORDER:
ROS
HPS-1000/Q
__________
__________
5618 Copley Drive
San Diego, CA 92111-7902
TEL: 858-565-8500
FAX: 858-565-8808
www.rosys.com
80-06003B 05APR04

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HPS-1000/Q and is the answer not in the manual?

Questions and answers

Summary of Contents for Ros HPS-1000/Q

  • Page 1 HPS-1000/Q DROPLIGHT SYSTEM OPERATING AND MAINTENANCE MANUAL SERIAL NUMBER: __________ SALES ORDER: __________ 5618 Copley Drive San Diego, CA 92111-7902 TEL: 858-565-8500 FAX: 858-565-8808 www.rosys.com 80-06003B 05APR04...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS WARRANTY ........................III CUSTOMER SERVICE ....................IV GENERAL DESCRIPTION ..................... 1 DESIGN FEATURES ...................... 2 SPECIFICATIONS ......................3 HPS-1000/Q DROPLIGHT .......................3 HPS-1000 IN-AIR BALLAST POWER SUPPLY..............3 CABLE MANAGEMENT SYSTEM...................3 INSTALLATION AND OPERATION ................4 OPERATIONAL CHECK ......................4 INSTALLATION........................4 MAINTENANCE......................
  • Page 3: Warranty

    This warranty shall be governed by the laws of the State of California. In the event the defect is determined to be within the terms of this warranty, then ROS agrees to repair and/or replace (at ROS’s discretion) the product or defective portion at no charge to the Purchaser.
  • Page 4: Customer Service

    CUSTOMER SERVICE ROS, Inc uses a worldwide network of stocking distributors and representatives who are familiar with our products and are able to provide assistance during installation and/or operation of these products. If you have any questions or problems with this product that are not covered by this manual or instruction, please contact our agent in your area, or contact us directly by phone, fax, or e-mail.
  • Page 5: General Description

    GENERAL DESCRIPTION The HPS-1000 Droplight System was designed specifically for use in nuclear reactor vessels and spent fuel storage pools. The light head uses a high-pressure sodium discharge light. Because of the very high efficiency, the 1000-watt HPS lamp produces the equivalent light of seven 1000-watt incandescent lights and will last ten times as long as an incandescent light used under the same conditions.
  • Page 6: Design Features

    DESIGN FEATURES The primary design features of the HPS-1000 Droplight System are as follows: 1. Exceptionally long life (10 times longer than an incandescent bulb). 2. Very high efficiency (140,000 lumens for 1000 watt light). 3. Direct plug in replacement of existing fixtures. 4.
  • Page 7: Specifications

    SPECIFICATIONS HPS-1000/Q DROPLIGHT POWER: 1000 Watts OPERATION DEPTH: 100 Feet LAMP TYPE: High Pressure Sodium Discharge LAMP OUTPUT: 140,000 Lumens (Initial Output) LAMP LIFETIME: 10 time longer than an incandescent bulb DIAMETER: 3.5 Inches LENGTH: 17 Inches including connector WEIGHT IN AIR: 5.25 Pounds...
  • Page 8: Installation And Operation

    If damage is detected a claim should be submitted to the freight carrier, with a copy to ROS, Inc. After the initial inspection, connect and operate the equipment as instructed in the following section.
  • Page 9: Maintenance

    MAINTENANCE The HPS-1000 Droplight system was designed to provide a long lifetime of service with very little maintenance. Maintenance is generally limited to cleaning and replacement of bulb assemblies. Ballasts are generally good for 5-7 years. After this period, the capacitor may change value due to heat and age or the striker may give out.
  • Page 10: Caution

    CAUTION LAMP AND STAINLESS STEEL SCREEN MAY BE VERY HOT AFTER PROLONGED OPERATION. EITHER WAIT FOR SCREEN AND BULB TO COOL OR USE PROTECTIVE GLOVES TO CHANGE LAMP ASSEMBLY. USE OF AN INCORRECT POWER SOURCE MAY CAUSE PERMANENT DAMAGE TO THE BALLAST POWER SUPPLY. DO NOT PLUG OR UNPLUG INTERCONNECT CABLES WITH THE POWER ON.
  • Page 11: Appendix

    APPENDIX Droplight HPS-1000 Drawings 80-02100 HPS-1000/Q Droplight Assembly 80-50114 Cable Management System, DLBA-1000 80-02109 Ballast Assy, In-Air Ballast, 115VAC, 60Hz, HPS-1000 80-02007 Wiring Diagram, In-Air Ballast, 115VAC, 60Hz, HPS-1000 80-06003B 05APR04...