Viessmann VITODENS 200-W Service Instructions Manual page 78

Table of Contents

Advertisement

Troubleshooting
Fault codes
(cont.)
Fault
Const.
code on
the dis-
play
C6
C7
X
Cd
X
CE
X
CF
dA
db
78
weath.-
System char-
comp.
acteristics
X
Control mode,
max. pump
speed
X
Control mode,
max. pump
speed
X
Control mode
X
Control mode
X
Control mode
X
Control mode
without room
influence
X
Control mode
without room
influence
Cause
Measures
Communica-
Check setting of
tion fault, var-
coding address
iable speed
"E5"
circulation
pump, heat-
ing circuit M2
Communica-
Check setting of
tion fault, var-
coding address
iable speed
"E5"
circulation
pump, heat-
ing circuit A1
Communica-
Check connections
tion fault
and the
Vitocom 100
Vitocom 100
(KM BUS)
Communica-
Check connections
tion fault –
and settings of
coding address
ext. exten-
"2E"
sion
Communica-
Replace the LON
tion fault,
communication
LON commu-
module
nication mod-
ule
Room tem-
Check the room
perature sen-
temperature sen-
sor, heating
sor, heating circuit
circuit A1
A1
shorted out
Room tem-
Check the room
perature sen-
temperature sen-
sor, heating
sor, heating circuit
circuit with
with mixer M2
mixer M2
shorted out