INSTALLATION

Installation typique

INSTALLATION
Installation typique
BASSIN ÉTANCHE AU GAZ PAR MINIMUM
TROU DE DÉGAGEMENT DIAM. 4,8 mm
(3/16 po) SUR LE TUYAU D'ÉCOULEMENT
LA POMPE DOIT ÊTRE INSTALLÉE SUR UNE SURFACE DURE.
N'INSTALLEZ JAMAIS LA POMPE SUR UNE SURFACE ARGILEUSE,
TERREUSE OU SABLEUSE.
12
PRISE DE COURANT DE MISE À LA TERRE À PROTECTION SÉPARÉE À UNE DISTANCE MINIMALE
DE 4 PI DU SOL
FIL D'ALIMENTATION DE L'INTERRUPTEUR À FLOTTEUR
CORDON D'ALIMENTATION DE LA
POMPE
CLAPET DE LA VANNE
CLAPET DE RETENUE
LA CANALISATION DE REFOULEMENT
DOIT ÊTRE PLUS PETITE QUE LA SORTIE
DE POMPE.
CANALISATION DE
VENTILATION DE
51 - 76 mm (2 ou 3 po)
FIL DE L'INTERRUPTEUR : 89 mm (3 1/2 po)
marche : 330 mm (13 po)
arrêt : 127 mm (5 po)
COUVERCLE DU BASSIN
INTERRUPTEUR À FLOTTEUR
VERTICAL
marche : 178 mm (7 po)
arrêt : 57 mm (2,25 po)