1. Introduction
The M-7033D is a 3-channel RTD Input module that is used for measuring temperatures
via an RTD sensor and supports Pt100, Ni120, and Pt1000 type sensors. The module
allows 2/3/4-wire RTD connections and features open wire detection. In addition, the M-
7033 also includes 3000 VDC intra-module isolation, and supports lead resistance
elimination for 3/4-wire connections.
2. Terminal Assignment
M-7033D 3 Channel RTD DAQ Module - QuickStart (May/2018)
ICP DAS USA, Inc. |
www.icpdas-usa.com
| 1-310-517-9888 | 24309 Narbonne Ave. Suite 200. Lomita, CA 90717
1

Advertisement

loading

Summary of Contents for ICP DAS USA M-7033D

  • Page 1 1. Introduction The M-7033D is a 3-channel RTD Input module that is used for measuring temperatures via an RTD sensor and supports Pt100, Ni120, and Pt1000 type sensors. The module allows 2/3/4-wire RTD connections and features open wire detection. In addition, the M- 7033 also includes 3000 VDC intra-module isolation, and supports lead resistance elimination for 3/4-wire connections.
  • Page 2: Block/ Wiring Diagram

    ▫ Analog output type: 0 ~ +10 V ▫ Baud Rate: 9600 bps ▫ Engineering unit format M-7033D 3 Channel RTD DAQ Module - QuickStart (May/2018) ICP DAS USA, Inc. | www.icpdas-usa.com | 1-310-517-9888 | 24309 Narbonne Ave. Suite 200. Lomita, CA 90717...
  • Page 3 It can select multi-options such as Baud Rate, Protocol, Checksum, and Format to search module. The default settings for the module can be found in Section 3. Click OK after selecting the COM port setting. M-7033D 3 Channel RTD DAQ Module - QuickStart (May/2018) ICP DAS USA, Inc. | www.icpdas-usa.com...
  • Page 4 DCON Utility Pro supports DCON and Modbus protocol for all ICPDAS and the others modules. 6. Configuration I/O module setting on PC M-7033D 3 Channel RTD DAQ Module - QuickStart (May/2018) ICP DAS USA, Inc. | www.icpdas-usa.com | 1-310-517-9888 | 24309 Narbonne Ave. Suite 200. Lomita, CA 90717...
  • Page 5 For M-7000 modules using the Modbus RTU protocol, use Function 04h to read the data from the input channels. See user manual Section 3.2 for details. M-7033D 3 Channel RTD DAQ Module - QuickStart (May/2018) ICP DAS USA, Inc. | www.icpdas-usa.com...
  • Page 6 If user doesn’t know command, user can select Address and ID, it will show some refer commands as below. User can select necessary command to test or debug modules. M-7033D 3 Channel RTD DAQ Module - QuickStart (May/2018) ICP DAS USA, Inc. | www.icpdas-usa.com...