Removing The Optional 6-Channel Expansion I/O Board; Replacing The 6-Channel Expansion I/O Board; Removing/Replacing The Connectivity Board - Emerson FB2100 Field Replacement Manual

Flow computer cpu enclosure and electronics
Hide thumbs Also See for FB2100:
Table of Contents

Advertisement

FB2100/FB2200 Flow Computer CPU Enclosure & Electronics Field Replacement Guide
D301803X012
November 2020

Removing the Optional 6-Channel Expansion I/O Board

1.
Remove the HMI module. See
2.
Disconnect the cable between the CPU enclosure and the sensor. See
Between the CPU Enclosure and the Sensor
3.
Detach the CPU enclosure from the battery compartment. See
the Battery Compartment
4.
Remove the CPU enclosure cover. See
5.
Remove the adapter board. See
6.
Remove the CPU board. See
7.
Remove the two standoffs closest to the connectivity board; these screw directly through the
board to connections on the CPU enclosure bottom.
The other two standoffs have separate screws underneath that hold them onto the expansion
I/O board. (If you are replacing the board itself because it failed, remove these standoffs and
screws as well so you can re-use them on the replacement board.)
8.
Carefully slide the 6-channel expansion I/O board out of its socket on the connectivity board and
set it aside.

Replacing the 6-Channel Expansion I/O Board

1.
If you removed standoffs that are held on the expansion I/O board, attach them to the new
replacement expansion I/O board. Torque standoffs to 1 to 2 in-lbs (0.1 to 0.2 N-m).
2.
Carefully slide the 6-channel expansion I/O board into its slot in the connectivity board and
make sure it is firmly in place.
3.
Secure the board to the bottom of the CPU enclosure by tightening the two standoffs that have
connections on the CPU enclosure. Torque standoffs 1 to 2 in-lbs (0.1 to 0.2 N-m).
4.
Attach the CPU board. See
5.
Reattach the adapter board. See
6.
Reattach the CPU enclosure cover. See
7.
Re-attach the CPU enclosure to the battery compartment. See
the Battery Compartment
8.
Re-connect the cable between the CPU enclosure and the sensor module.
9.
Reattach the HMI module. See

Removing/Replacing the Connectivity Board

UL Listed Connectivity Board Field Installed Accessory Kit for Use in Class I, Division 2, Groups A, B, C,
and D
18
on page 7.
Replacing the CPU Board
on page 9.
Flow Computer Connectivity Board Field Installed Accessory Kit Part No. 400211010-KIT for
use with UL Listed Model Series FB2100 and FB2200.
Removing the HMI Module
on page 7.
Removing the CPU Enclosure Cover (Top)
Removing the Adapter Board
Removing the CPU Board
on page 14.
on page 16.
Replacing the Adapter Board
Replacing the CPU Enclosure Cover (Top)
Replacing the HMI Module
on page 6.
Disconnecting the Cable
Detaching the CPU Enclosure from
on page 10.
on page 12.
on page 14.
on page 11.
Re-attaching the CPU Enclosure to
on page 6.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fb2200

Table of Contents