Introduction Thank you for purchasing the Ubiquiti Networks® EdgeRouter PRO. This Quick Start Guide is designed to guide ™ you through installation and also includes warranty terms. Package Contents EdgeRouter PRO Mounting Screws Cage Nuts (#10-32 x 5/8", Qty. 4) (#10-32 x 5/8", Qty.
AC ground of the power supply. We recommend that you protect your networks from harmful outdoor environments and destructive ESD events with industrial-grade, shielded Ethernet cable from Ubiquiti Networks. For more details, visit: www.ubnt.com/toughcable WARNING: To reduce the risk of fire or electric shock, do not expose the EdgeRouter to rain or moisture.
https://arttel.ru/ Hardware Overview Front Panel Ports SFP (eth6-eth7) Console RJ45 (eth0-eth7) Interface Description RJ45 serial console port for Command Line Interface (CLI) management. Use an RJ45-to-DB9, serial console cable, also known as a rollover cable, to connect the Console port to your computer. (If your computer does not have a DB9 port, then you will also need a DB9 adapter.) Then Console...
Page 5
https://arttel.ru/ Front Panel Button Reset Button Description There are two methods to reset the EdgeRouter PRO to factory defaults: • Runtime reset (recommended) The EdgeRouter PRO should be running after bootup is complete. Press and hold the Reset button for about 10 seconds until the right LED on RJ45 port eth7 starts flashing and then becomes solidly lit.
Page 6
https://arttel.ru/ Front Panel LEDs The LEDs on the left side of the RJ45 ports are not used at this time. Below is a description of the other LEDs: RJ45: Speed/Link/Act SFP: Speed/Link/Act Power State Status No Link Link Established at Amber 10/100 Mbps Link Activity at...
https://arttel.ru/ Back Panel Mounting Holes Mounting Holes Fans Power Ventilation Holes Note: There are additional ventilation holes on the sides of the EdgeRouter PRO. Hardware Installation WARNING: FAILURE TO PROVIDE PROPER VENTILATION MAY CAUSE FIRE HAZARD. KEEP AT LEAST 20 MM OF CLEARANCE NEXT TO THE VENTILATION HOLES FOR ADEQUATE AIRFLOW.
Page 8
https://arttel.ru/ 2. Connect the Power Cord to the Power port. 3. Connect the other end of the Power Cord to a power outlet. https://arttel.ru/shop/marshrutizatory/ubiqu...
Page 9
https://arttel.ru/ Using SFP Ports To use an SFP port: 1. Remove the protective plug covering the SFP port. 2. Plug a fiber SFP module into the SFP port. Note: The corresponding RJ45 port will be deactivated. 3. Connect a fiber optic cable to the fiber SFP module. Then connect the other end of the cable to another fiber device.
Page 10
Press enter (PC) or return (Mac). 4. The login screen will appear. Enter ubnt in the Username and Password fields. Read the Ubiquiti License Agreement, and check the box next to I agree to the terms of this License Agreement to accept it.
https://arttel.ru/ Specifications EdgeRouter PRO Dimensions 484 x 164 x 44 mm (19.06 x 6.46 x 1.73") Weight 2.3 kg (5.07 lb) Max. Power Consumption 40 W Power Method 110 - 240VAC Power Supply Internal AC/DC Power Adapter, 60 W (24V, 2.5A) Button Reset Power...
https://arttel.ru/ Safety Notices Read, follow, and keep these instructions. Heed all warnings. Only use attachments/accessories specified by the manufacturer. WARNING: Failure to provide proper ventilation may cause fire hazard. Keep at least 20 mm of clearance next to the ventilation holes for adequate airflow. WARNING: To reduce the risk of fire or electric shock, do not expose this product to rain or moisture.
Ubiquiti MAC label, or is missing any other original Ubiquiti label(s); or (VII) has not been received by Ubiquiti within 30 days of issuance of the RMA. In addition, the above warranty shall apply only if: the product has been properly installed and used at all times in accordance, and in all material respects, with the applicable Product documentation;...
SUBJECT TO LIMITATIONS, INTERRUPTIONS, DELAYS, CANCELLATIONS AND OTHER PROBLEMS INHERENT IN THE USE OF COMMUNICATIONS FACILITIES. UBIQUITI NETWORKS, ITS AFFILIATES AND ITS AND THEIR THIRD PARTY PROVIDERS ARE NOT RESPONSIBLE FOR ANY INTERRUPTIONS, DELAYS, CANCELLATIONS, DELIVERY FAILURES, DATA LOSS, CONTENT CORRUPTION, PACKET LOSS, OR OTHER DAMAGE RESULTING FROM ANY OF THE FOREGOING.
https://arttel.ru/ Note Some countries, states and provinces do not allow exclusions of implied warranties or conditions, so the above exclusion may not apply to you. You may have other rights that vary from country to country, state to state, or province to province. Some countries, states and provinces do not allow the exclusion or limitation of liability for incidental or consequential damages, so the above limitation may not apply to you.
https://arttel.ru/ Australia and New Zealand Warning: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. CE Marking CE marking on this product represents the product is in compliance with all directives that are applicable to it.
Page 17
https://arttel.ru/ Español La Directiva 2012/19/UE exige que los equipos que lleven este símbolo en el propio aparato y/o en su embalaje no deben eliminarse junto con otros residuos urbanos no seleccionados. El símbolo indica que el producto en cuestión debe separarse de los residuos domésticos convencionales con vistas a su eliminación.
Ezennel UBIQUITI NETWORKS kijelenti, hogy ez a UBIQUITI NETWORKS készülék megfelel az alapvető követelményeknek és más [Hungarian] vonatkozó 2014/30/EU, 2014/35/EU irányelvek rendelkezéseit. Íslenska Hér, UBIQUITI NETWORKS, því yfir að þetta UBIQUITI NETWORKS tæki er í samræmi við grunnkröfur og önnur viðeigandi ákvæði tilskipana [Icelandic] 2014/30/ESB, 2014/35/ESB. Italiano Con la presente, UBIQUITI NETWORKS, dichiara che questo dispositivo UBIQUITI NETWORKS, è...
[Slovak] a ďalšími relevantnými ustanoveniami smernice 2014/30/EÚ, 2014/35/EÚ. Español Por medio de la presente UBIQUITI NETWORKS declara que este dispositivo UBIQUITI NETWORKS, cumple con los requisitos [Spanish] esenciales y cualesquiera otras disposiciones aplicables o exigibles de las Directivas 2014/30/UE, 2014/35/UE.