Daikin FTXS-L Series Engineering Data page 25

Hide thumbs Also See for FTXS-L Series:
Table of Contents

Advertisement

Capacity Tables
Symbols:
AFR
: Airflow rate
BF
: Bypass factor
EWB
: Entering wet bulb temp.
EDB
: Entering dry bulb temp.
TC
: Total capacity
SHC
: Sensible heat capacity
PI
: Power input
24
Note:
(m
/min.)
1. Ratings shown are net capacities which include a deduction for indoor fan
3
motor heat.
2.
3. TC, PI and SHC must be calculated by interpolation using the figures in the
(°C) / (°F)
above tables. (Figures out of the tables should not be used for calculation.)
(°C) / (°F)
4. SHC values not included in the table must be calculated using interpolation
with values of direct proportion.
(kW) / (kBtu/h)
5. Capacities are based on the following conditions.
(kW) / (kBtu/h)
Corresponding refrigerant piping length : 25 ft
Level difference : 0 ft
(kW)
6. Airflow rate (AFR) and Bypass factor (BF) are tabulated above table.
7. Cooling capacity at –15°C / 5°F
Temp: Celsius
TC, SHC, PI: kW
60 Hz, 208 - 230 V
EWB
14.0
Temp: Fahrenheit
TC, SHC: kBtu/h
PI: kW
60 Hz, 208 - 230 V
EWB
57.2
shows nominal (rated) capacities and power input.
INDOOR
OUTDOOR
EDB
–15 (°CDB)
°C
°C
TC
SHC
PI
20.0
3.54
2.66
0.23
INDOOR
OUTDOOR
EDB
5 (°FDB)
°F
°F
TC
SHC
PI
68.0
12.08
9.08
0.23
Split Type Air Conditioners FTXS-L / FDXS-L Series
EDUS091128
3D074636