Standard for single wire confection.
16
B
150
638
the larger faston connector always mentioned at first. (Nathan drawing number controlling)
lenght in mm within a 50 mm raster
colour
B = black (phase conductor)
R = red
BR = brown
BL = blue (neutral conductor)
W = white
YG = yellow-green (ground bonding/ earthing connection)
cross section
16 = AWG 16 (prefered usage)
Q1.5 = H07VK 1,5mm² (prefered usage)
wire designation:
P + lfd Nr. = AWG single wire black, red, blue, brown or white
E + lfd Nr. = AWG single wire green- yellow
L + lfd Nr. = twisted AWG double wire, lenght specification always in twisted condition
FQL + lfd Nr. = crossover wiring H07VK
Regarding special wirings like wiring harness or similar, drawings will be prepared and appropriate
Stand
-
I
485 W
Z
I
I = completely insulated with black shrinktube or appropriate sleeve
IT = partly insulated; only crimp connection insulated.
no marking = without insulation
Z = with additional junction
no marking = without additional junction
W = angled faston
no marking = straight faston
Faston connector brass tin-plated DIN 46245
638 = 6,3 * 0,8 [mm]
488 = 4,8 * 0,8 [mm]
485 = 4,8 * 0,5 [mm]
288 = 2,8 * 0,8 [mm]
285 = 2,8 * 0,5 [mm]
abiso = 5mm bared and tin-plated (teilabzug)
text for special constructions, (for example. 4mm ringshaped faston)
drawing numbers will be stored in the article archive.
17. Jun 04
1015
style 1015 according UL specifications
if fully insulated (I) insulation with blue shrinktube
if partly insulated (IT) use IF 602 485 .
if fully insulated (I) insulation with blue shrinktube
if partly insulated (IT) use IF 602 485