ADF Web HD67D40-B2 User Manual

ADF Web HD67D40-B2 User Manual

Lorawan / snmp manager - converter
Hide thumbs Also See for HD67D40-B2:

Advertisement

Quick Links

Industrial Electronic Devices
User Manual
Revision 1.000
English
LoRaWAN / SNMP Manager - Converter
(Order Code: HD67D40-B2-868MHz
For Website information:
www.adfweb.com?Product=HD67D40-B2
For Price information:
www.adfweb.com?Price=HD67D40-B2-868MHz
Benefits and Main Features:
Very easy to configure
Power Supply 18...35V DC and 8...24 V AC
Temperature range: -40°C/+85°C (-40°F/+185°F)
User Manual
ADFweb.com S.r.l.
User Manual LoRaWAN / SNMP Manager
Document code: MN67D40_ENG
For others LoRaWAN products, see also the following links:
Converter LoRaWAN to
www.adfweb.com?Product=HD67D01
www.adfweb.com?Product=HD67D02
www.adfweb.com?Product=HD67D03
www.adfweb.com?Product=HD67D04
www.adfweb.com?Product=HD67D05
www.adfweb.com?Product=HD67D15
www.adfweb.com?Product=HD67D16
www.adfweb.com?Product=HD67D17
www.adfweb.com?Product=HD67D18
www.adfweb.com?Product=HD67D19
www.adfweb.com?Product=HD67D20
www.adfweb.com?Product=HD67D21
www.adfweb.com?Product=HD67D22
www.adfweb.com?Product=HD67D23
www.adfweb.com?Product=HD67D24
www.adfweb.com?Product=HD67D25
www.adfweb.com?Product=HD67D26
www.adfweb.com?Product=HD67D27
www.adfweb.com?Product=HD67D28
www.adfweb.com?Product=HD67D29
www.adfweb.com?Product=HD67D30
www.adfweb.com?Product=HD67D31
www.adfweb.com?Product=HD67D32
www.adfweb.com?Product=HD67D33
www.adfweb.com?Product=HD67D34
www.adfweb.com?Product=HD67D35
www.adfweb.com?Product=HD67D36
www.adfweb.com?Product=HD67D37
www.adfweb.com?Product=HD67D38
www.adfweb.com?Product=HD67D39
www.adfweb.com?Product=HD67D41
Revision 1.000
Page 1 of 28
(LoRaWAN)
(LoRaWAN)
(Modbus TCP Master)
(Modbus TCP Slave)
(Serial)
(M-Bus)
(BACnet Master)
(BACnet Slave)
(Ethernet)
(CAN)
(CANopen)
(DeviceNet Master)
(DeviceNet Slave)
(DMX)
(EtherNet/IP Master)
(EtherNet/IP Slave)
(J1939)
(KNX)
(NMEA 0183)
(NMEA 2000)
(PROFIBUS Master)
(PROFIBUS Slave)
(PROFINET Master)
(PROFINET Slave)
(IEC61850 Client)
(IEC61850 Server)
(MQTT)
(OPC UA Client)
(OPC UA Server)
(S7comm)
(SNMP Agent)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HD67D40-B2 and is the answer not in the manual?

Questions and answers

Summary of Contents for ADF Web HD67D40-B2

  • Page 1 Revision 1.000 Page 1 of 28 Industrial Electronic Devices User Manual Revision 1.000 English LoRaWAN / SNMP Manager - Converter (Order Code: HD67D40-B2-868MHz For others LoRaWAN products, see also the following links: For Website information: www.adfweb.com?Product=HD67D40-B2 Converter LoRaWAN to www.adfweb.com?Product=HD67D01 (LoRaWAN) www.adfweb.com?Product=HD67D02...
  • Page 2: Table Of Contents

    User Manual LoRaWAN / SNMP Manager Document code: MN67D40_ENG Revision 1.000 Page 2 of 28 Industrial Electronic Devices INDEX: UPDATED DOCUMENTATION: Dear customer, we thank you for your attention and we remind you that Page you need to check that the following document is: INDEX UPDATED DOCUMENTATION Updated...
  • Page 3: Security Alert

    User Manual LoRaWAN / SNMP Manager Document code: MN67D40_ENG Revision 1.000 Page 3 of 28 Industrial Electronic Devices SECURITY ALERT: ENERAL NFORMATION To ensure safe operation, the device must be operated according to the instructions in the manual. When using the device, legal and safety regulation are required for each individual application.
  • Page 4: Example Of Connection

    User Manual LoRaWAN / SNMP Manager Document code: MN67D40_ENG Revision 1.000 Page 4 of 28 Industrial Electronic Devices EXAMPLE OF CONNECTION: ADFweb.com S.r.l.
  • Page 5: Connection Scheme

    User Manual LoRaWAN / SNMP Manager Document code: MN67D40_ENG Revision 1.000 Page 5 of 28 Industrial Electronic Devices CONNECTION SCHEME: Figure 1: Connection scheme for HD67D40-B2-xxxMHz ADFweb.com S.r.l.
  • Page 6: Characteristics

    Revision 1.000 Page 6 of 28 Industrial Electronic Devices CHARACTERISTICS: The HD67D40-B2 is a LoRaWAN / SNMP Converter. It allows the following characteristics: Electrical isolation between SNMP and Power Supply; Two-directional information between LoRaWAN bus and SNMP bus; Mountable on 35mm Rail DIN;...
  • Page 7: Power Supply

    The devices can be powered at 8…24V AC and 12…35V DC. For more details see the two tables below. Vmin Vmax Vmin Vmax Consumption at 24V DC: Device Consumption [W/VA] HD67D40-B2-xxxMHz Caution: Not reverse the polarity power HD67D40-B2-xxxMHz ADFweb.com S.r.l.
  • Page 8: Function Modes

    User Manual LoRaWAN / SNMP Manager Document code: MN67D40_ENG Revision 1.000 Page 8 of 28 Industrial Electronic Devices FUNCTION MODES: The device has got two functions mode depending of the position of the ‘Dip1 of Dip-Switch A’: The first, with ‘Dip1 of Dip-Switch A’ at “OFF” position, is used for the normal working of the device. The second, with ‘Dip1 of Dip-Switch A’...
  • Page 9: Leds

    User Manual LoRaWAN / SNMP Manager Document code: MN67D40_ENG Revision 1.000 Page 9 of 28 Industrial Electronic Devices LEDS: The device has got four LEDs that are used to give information of the functioning status. The various meanings of the LEDs are described in the table below. Normal Mode Boot Mode Blinks quickly: Boot state...
  • Page 10: Lorawan

    User Manual LoRaWAN / SNMP Manager Document code: MN67D40_ENG Revision 1.000 Page 10 of 28 Industrial Electronic Devices LORAWAN: The LoRaWAN® specification is a Low Power, Wide Area (LPWA) networking protocol designed to wirelessly connect battery operated ‘things’ to the internet in regional, national or global networks, and targets key Internet of Things (IoT) requirements such as bi- directional communication, end-to-end security, mobility and localization services.
  • Page 11: Ethernet

    The Ethernet port is used for programming the device and for SNMP communication. The Ethernet connection must be made using Connector2 of HD67D40-B2 with at least a Category 5E cable. The maximum length of the cable should not exceed 100m. The cable has to conform to the T568 norms relative to connections in cat.5 up to 100 Mbps. To connect the device to an Hub/Switch is recommended the use of a straight cable, to connect the device to a PC is recommended the use of a cross cable.
  • Page 12: Use Of Compositor Sw67D40

    User Manual LoRaWAN / SNMP Manager Document code: MN67D40_ENG Revision 1.000 Page 12 of 28 Industrial Electronic Devices USE OF COMPOSITOR SW67D40: To configure the Converter, use the available software that runs with Windows called SW67D40. It is downloadable on the site www.adfweb.com and its operation is described in this document.
  • Page 13: New Configuration / Open Configuration

    User Manual LoRaWAN / SNMP Manager Document code: MN67D40_ENG Revision 1.000 Page 13 of 28 Industrial Electronic Devices NEW CONFIGURATION / OPEN CONFIGURATION: “New Configuration” button creates the folder which contains the entire device’s configuration. A device’s configuration can also be imported or exported: To clone the configurations of a Programmable “LoRaWAN / SNMP Manager - Converter”...
  • Page 14: Software Options

    User Manual LoRaWAN / SNMP Manager Document code: MN67D40_ENG Revision 1.000 Page 14 of 28 Industrial Electronic Devices SOFTWARE OPTIONS: By pressing the “Settings” ( ) button there is the possibility to change the language of the software and check the updatings for the compositor.
  • Page 15 User Manual LoRaWAN / SNMP Manager Document code: MN67D40_ENG Revision 1.000 Page 15 of 28 Industrial Electronic Devices In the section “Software Settings”, it is possible to enable/disable some keyboard’s commands for an easier navigation inside the tables contained in the different sections of the software.
  • Page 16: Set Communication

    User Manual LoRaWAN / SNMP Manager Document code: MN67D40_ENG Revision 1.000 Page 16 of 28 Industrial Electronic Devices SET COMMUNICATION: By Pressing the “Set Communication” button from the main window for SW67D40 (Fig. 2) the window “Set Communication” appears (Fig. 3). The means of the fields for the “LoRaWAN”...
  • Page 17 User Manual LoRaWAN / SNMP Manager Document code: MN67D40_ENG Revision 1.000 Page 17 of 28 Industrial Electronic Devices The means of the fields for “SNMP Manager” are: In the field “IP ADDRESS” the IP address that you want to give to the SNMP side is defined; In the field “SUBNET Mask”...
  • Page 18: Lorawan Access

    User Manual LoRaWAN / SNMP Manager Document code: MN67D40_ENG Revision 1.000 Page 18 of 28 Industrial Electronic Devices LORAWAN ACCESS: By Pressing the “LoRaWAN Access” button from the main window for SW67D40 (Fig. 2) the window “Set LoRaWAN Access” appears (Fig. 4).
  • Page 19 User Manual LoRaWAN / SNMP Manager Document code: MN67D40_ENG Revision 1.000 Page 19 of 28 Industrial Electronic Devices WAN D OWNLINK Figure 4b: “LoRaWAN Access  LoRaWAN Downlink” window The means of the fields are: If the field “Enable” is checked, the LoRaWAN message is enabled; In the field “Start Byte”...
  • Page 20: Snmp Set Access

    User Manual LoRaWAN / SNMP Manager Document code: MN67D40_ENG Revision 1.000 Page 20 of 28 Industrial Electronic Devices SNMP SET ACCESS: Figure 5: “Set SNMP Manager Access” window By Pressing the “SNMP Manager” button from the main window for SW67D40 (Fig. 2) the window “Set SNMP Manager Access” appears (Fig.
  • Page 21 User Manual LoRaWAN / SNMP Manager Document code: MN67D40_ENG Revision 1.000 Page 21 of 28 Industrial Electronic Devices In the field “Num Bytes” it is possible to select define the dimension of the SNMP data; In the field “Conversion” it is possible to select the conversion to apply to the data read/written from/to the SNMP Agent; If the field “Cancel”...
  • Page 22: Update Device

    User Manual LoRaWAN / SNMP Manager Document code: MN67D40_ENG Revision 1.000 Page 22 of 28 Industrial Electronic Devices UPDATE DEVICE: By pressing the “Update Device” button, it is possible to load the created Configuration into the device; and also the Firmware, if necessary. This by using the Ethernet port.
  • Page 23 User Manual LoRaWAN / SNMP Manager Document code: MN67D40_ENG Revision 1.000 Page 23 of 28 Industrial Electronic Devices Note: When you receive the device, for the first time, you also have to update the Firmware in the HD67D40 device. Warning: If Fig.
  • Page 24: Lorawan Payload

    User Manual LoRaWAN / SNMP Manager Document code: MN67D40_ENG Revision 1.000 Page 24 of 28 Industrial Electronic Devices LORAWAN PAYLOAD The LoRAWAN messages in Uplink and Downlink are structured into a defined format in order to recognize them from LoRaWAN gateway side and to understand to which bytes of the internal memory array they are associated.
  • Page 25: Mechanical Dimensions

    User Manual LoRaWAN / SNMP Manager Document code: MN67D40_ENG Revision 1.000 Page 25 of 28 Industrial Electronic Devices MECHANICAL DIMENSIONS: Figure 7: Mechanical dimensions scheme for HD67D40-B2 ADFweb.com S.r.l.
  • Page 26: Ordering Informations

    Enclosure Type B: Modulbox 4M, 35mm DIN Rail mounting Device Family HD67D40: LoRaWAN / SNMP Manager - Converter Order Code: HD67D40-B2-868MHz LoRaWAN / SNMP Manager – Converter ACCESSORIES: Order Code: AC34011 35mm Rail DIN - Power Supply 220/240V AC 50/60Hz – 12 V DC Order Code: AC34012 35mm Rail DIN - Power Supply 220/240V AC 50/60Hz –...
  • Page 27: Disclaimer

    User Manual LoRaWAN / SNMP Manager Document code: MN67D40_ENG Revision 1.000 Page 27 of 28 Industrial Electronic Devices DISCLAIMER: All technical content within this document can be modified without notice. The content of the document is a under continual renewal. For losses due to fire, earthquake, third party access or other accidents, or intentional or accidental abuse, misuse, or use under abnormal conditions repairs are charged to the user.
  • Page 28: Warranties And Technical Support

    User Manual LoRaWAN / SNMP Manager Document code: MN67D40_ENG Revision 1.000 Page 28 of 28 Industrial Electronic Devices WARRANTIES AND TECHNICAL SUPPORT: For fast and easy technical support for your ADFweb.com SRL products, consult our internet support at www.adfweb.com. Otherwise contact us at the address support@adfweb.com RETURN POLICY: If while using your product you have any problem and you wish to exchange or repair it, please do the following: Obtain a Product Return Number (PRN) from our internet support at www.adfweb.com.

This manual is also suitable for:

Hd67d41-b2Hd67d40-b2-868mhzHd67d41-b2-868mhz

Table of Contents