ADF Web HD67D03-B2-868MHz User Manual

ADF Web HD67D03-B2-868MHz User Manual

Lorawan/modbus tcp master-converter

Advertisement

Quick Links

Industrial Electronic Devices
User Manual
Revision 1.000
English
LoRaWAN / Modbus TCP Master - Converter
(Order Code: HD67D03-B2-868MHz)
For Website information:
www.adfweb.com?Product=HD67D03-B2
For Price information:
www.adfweb.com?Price=HD67D03-B2-868MHz
Benefits and Main Features:
Very easy to configure
Power Supply 18...35V DC and 8...24 V AC
Temperature range: -40°C/+85°C (-40°F/+185°F)
User Manual
ADFweb.com S.r.l.
User Manual LoRaWAN / Modbus TCP Master
Document code: MN67D03_ENG
For others LoRaWAN products, see also the following links:
Converter LoRaWAN to
www.adfweb.com?Product=HD67D01
www.adfweb.com?Product=HD67D02
www.adfweb.com?Product=HD67D04
www.adfweb.com?Product=HD67D05
www.adfweb.com?Product=HD67D15
www.adfweb.com?Product=HD67D16
www.adfweb.com?Product=HD67D17
www.adfweb.com?Product=HD67D18
www.adfweb.com?Product=HD67D19
www.adfweb.com?Product=HD67D20
www.adfweb.com?Product=HD67D21
www.adfweb.com?Product=HD67D22
www.adfweb.com?Product=HD67D23
www.adfweb.com?Product=HD67D24
www.adfweb.com?Product=HD67D25
www.adfweb.com?Product=HD67D26
www.adfweb.com?Product=HD67D27
www.adfweb.com?Product=HD67D28
www.adfweb.com?Product=HD67D29
www.adfweb.com?Product=HD67D30
www.adfweb.com?Product=HD67D31
www.adfweb.com?Product=HD67D32
www.adfweb.com?Product=HD67D33
www.adfweb.com?Product=HD67D34
www.adfweb.com?Product=HD67D35
www.adfweb.com?Product=HD67D36
www.adfweb.com?Product=HD67D37
www.adfweb.com?Product=HD67D38
www.adfweb.com?Product=HD67D39
www.adfweb.com?Product=HD67D40
www.adfweb.com?Product=HD67D41
Revision 1.000
Page 1 of 29
(Modbus Master)
(Modbus Slave)
(Modbus TCP Slave)
(Serial)
(M-Bus)
(BACnet Master)
(BACnet Slave)
(Ethernet)
(CAN)
(CANopen)
(DeviceNet Master)
(DeviceNet Slave)
(DMX)
(EtherNet/IP Master)
(EtherNet/IP Slave)
(J1939)
(KNX)
(NMEA 0183)
(NMEA 2000)
(PROFIBUS Master)
(PROFIBUS Slave)
(PROFINET Master)
(PROFINET Slave)
(IEC61850 Client)
(IEC61850 Server)
(MQTT)
(OPC UA Client)
(OPC UA Server)
(S7comm)
(SNMP Manager)
(SNMP Agent)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HD67D03-B2-868MHz and is the answer not in the manual?

Questions and answers

Summary of Contents for ADF Web HD67D03-B2-868MHz

  • Page 1 Page 1 of 29 Industrial Electronic Devices User Manual Revision 1.000 English LoRaWAN / Modbus TCP Master - Converter (Order Code: HD67D03-B2-868MHz) For others LoRaWAN products, see also the following links: For Website information: www.adfweb.com?Product=HD67D03-B2 Converter LoRaWAN to www.adfweb.com?Product=HD67D01 (Modbus Master) www.adfweb.com?Product=HD67D02...
  • Page 2: Table Of Contents

    User Manual LoRaWAN / Modbus TCP Master Document code: MN67D03_ENG Revision 1.000 Page 2 of 29 Industrial Electronic Devices INDEX: UPDATED DOCUMENTATION: Dear customer, we thank you for your attention and we remind you that Page you need to check that the following document is: INDEX UPDATED DOCUMENTATION Updated...
  • Page 3: Security Alert

    User Manual LoRaWAN / Modbus TCP Master Document code: MN67D03_ENG Revision 1.000 Page 3 of 29 Industrial Electronic Devices SECURITY ALERT: ENERAL NFORMATION To ensure safe operation, the device must be operated according to the instructions in the manual. When using the device, legal and safety regulation are required for each individual application.
  • Page 4: Example Of Connection

    User Manual LoRaWAN / Modbus TCP Master Document code: MN67D03_ENG Revision 1.000 Page 4 of 29 Industrial Electronic Devices EXAMPLE OF CONNECTION: ADFweb.com S.r.l.
  • Page 5: Connection Scheme

    User Manual LoRaWAN / Modbus TCP Master Document code: MN67D03_ENG Revision 1.000 Page 5 of 29 Industrial Electronic Devices CONNECTION SCHEME: Figure 1: Connection scheme for HD67D03-B2-xxxMHz ADFweb.com S.r.l.
  • Page 6: Characteristics

    User Manual LoRaWAN / Modbus TCP Master Document code: MN67D03_ENG Revision 1.000 Page 6 of 29 Industrial Electronic Devices CHARACTERISTICS: The HD67D03-B2 is a LoRaWAN / Modbus TCP Master Converter. It allows the following characteristics: Electrical isolation between Modbus TCP and Power Supply; Mountable on 35mm Rail DIN;...
  • Page 7: Power Supply

    User Manual LoRaWAN / Modbus TCP Master Document code: MN67D03_ENG Revision 1.000 Page 7 of 29 Industrial Electronic Devices POWER SUPPLY: The devices can be powered at 8…24V AC and 12…35V DC. For more details see the two tables below. Vmin Vmax Vmin...
  • Page 8: Function Modes

    User Manual LoRaWAN / Modbus TCP Master Document code: MN67D03_ENG Revision 1.000 Page 8 of 29 Industrial Electronic Devices FUNCTION MODES: The device has got two functions mode depending of the position of the ‘Dip1 of Dip-Switch A’: The first, with ‘Dip1 of Dip-Switch A’ at “OFF” position, is used for the normal working of the device. The second, with ‘Dip1 of Dip-Switch A’...
  • Page 9: Leds

    User Manual LoRaWAN / Modbus TCP Master Document code: MN67D03_ENG Revision 1.000 Page 9 of 29 Industrial Electronic Devices LEDS: The device has got four LEDs that are used to give information of the functioning status. The various meanings of the LEDs are described in the table below. Normal Mode Boot Mode Blinks quickly: Boot state...
  • Page 10: Lorawan

    User Manual LoRaWAN / Modbus TCP Master Document code: MN67D03_ENG Revision 1.000 Page 10 of 29 Industrial Electronic Devices LORAWAN: The LoRaWAN® specification is a Low Power, Wide Area (LPWA) networking protocol designed to wirelessly connect battery operated ‘things’ to the internet in regional, national or global networks, and targets key Internet of Things (IoT) requirements such as bi- directional communication, end-to-end security, mobility and localization services.
  • Page 11: Ethernet

    User Manual LoRaWAN / Modbus TCP Master Document code: MN67D03_ENG Revision 1.000 Page 11 of 29 Industrial Electronic Devices ETHERNET: The Ethernet port is used for programming the device and for Modbus TCP communication. The Ethernet connection must be made using Connector2 of HD67D03-B2 with at least a Category 5E cable. The maximum length of the cable should not exceed 100m.
  • Page 12: Use Of Compositor Sw67D03

    User Manual LoRaWAN / Modbus TCP Master Document code: MN67D03_ENG Revision 1.000 Page 12 of 29 Industrial Electronic Devices USE OF COMPOSITOR SW67D03: To configure the Converter, use the available software that runs with Windows called SW67D03. It is downloadable on the site www.adfweb.com and its operation is described in this document.
  • Page 13: New Configuration / Open Configuration

    User Manual LoRaWAN / Modbus TCP Master Document code: MN67D03_ENG Revision 1.000 Page 13 of 29 Industrial Electronic Devices NEW CONFIGURATION / OPEN CONFIGURATION: “New Configuration” button creates the folder which contains the entire device’s configuration. A device’s configuration can also be imported or exported: To clone the configurations of a Programmable “LoRaWAN / Modbus TCP Master - Converter”...
  • Page 14: Software Options

    User Manual LoRaWAN / Modbus TCP Master Document code: MN67D03_ENG Revision 1.000 Page 14 of 29 Industrial Electronic Devices SOFTWARE OPTIONS: By pressing the “Settings” ( ) button there is the possibility to change the language of the software and check the updatings for the compositor.
  • Page 15 User Manual LoRaWAN / Modbus TCP Master Document code: MN67D03_ENG Revision 1.000 Page 15 of 29 Industrial Electronic Devices In the section “Software Settings”, it is possible to enable/disable some keyboard’s commands for an easier navigation inside the tables contained in the different sections of the software.
  • Page 16: Set Communication

    User Manual LoRaWAN / Modbus TCP Master Document code: MN67D03_ENG Revision 1.000 Page 16 of 29 Industrial Electronic Devices SET COMMUNICATION: By Pressing the “Set Communication” button from the main window for SW67D03 (Fig. 2) the window “Set Communication” appears (Fig. 3). The means of the fields for the “LoRaWAN”...
  • Page 17 User Manual LoRaWAN / Modbus TCP Master Document code: MN67D03_ENG Revision 1.000 Page 17 of 29 Industrial Electronic Devices The means of the fields for the “Modbus TCP Master” section are: In the fields “IP ADDRESS” the IP address of Modbus TCP side of the converter is defined; In the fields “SUBNET Mask”...
  • Page 18: Lorawan Access

    User Manual LoRaWAN / Modbus TCP Master Document code: MN67D03_ENG Revision 1.000 Page 18 of 29 Industrial Electronic Devices LORAWAN ACCESS: By Pressing the “LoRaWAN Access” button from the main window for SW67D03 (Fig. 2) the window “Set LoRaWAN Access” appears (Fig. This section is used to define the LoRAWAN messages where the converter will place the data read from Modbus TCP (Uplink) and the LoRAWAN messages that the converter will take (Downlink) for writing the data to Modbus TCP.
  • Page 19 User Manual LoRaWAN / Modbus TCP Master Document code: MN67D03_ENG Revision 1.000 Page 19 of 29 Industrial Electronic Devices WAN D OWNLINK Figure 4b: “LoRAWAN Access  LoRaWAN Downlink” window The means of the fields are: If the field “Enable” is checked, the LoRaWAN message is enabled; In the field “Start Byte”...
  • Page 20: Modbus Set Access

    User Manual LoRaWAN / Modbus TCP Master Document code: MN67D03_ENG Revision 1.000 Page 20 of 29 Industrial Electronic Devices MODBUS SET ACCESS: By pressing the “Modbus Set Access” button from the main window for SW67D03 (Fig. 2) the window “Set Modbus TCP Master Access” appears.
  • Page 21 User Manual LoRaWAN / Modbus TCP Master Document code: MN67D03_ENG Revision 1.000 Page 21 of 29 Industrial Electronic Devices In the field “Position” the address of the internal array where placing the information is defined; In the field “Start Bit” the starting bit of the first byte of the field “Position” is defined; If the field “Swap”...
  • Page 22 User Manual LoRaWAN / Modbus TCP Master Document code: MN67D03_ENG Revision 1.000 Page 22 of 29 Industrial Electronic Devices ODBUS RITE The means of the fields are: If the field “Enable” is checked, the Modbus request is enabled; In the field “Slave IP Address”...
  • Page 23: Update Device

    User Manual LoRaWAN / Modbus TCP Master Document code: MN67D03_ENG Revision 1.000 Page 23 of 29 Industrial Electronic Devices UPDATE DEVICE: By pressing the “Update Device” button, it is possible to load the created Configuration into the device; and also the Firmware, if necessary. This by using the Ethernet port.
  • Page 24 User Manual LoRaWAN / Modbus TCP Master Document code: MN67D03_ENG Revision 1.000 Page 24 of 29 Industrial Electronic Devices Note: When you receive the device, for the first time, you also have to update the Firmware in the HD67D03 device. Warning: If Fig.
  • Page 25: Lorawan Payload

    User Manual LoRaWAN / Modbus TCP Master Document code: MN67D03_ENG Revision 1.000 Page 25 of 29 Industrial Electronic Devices LORAWAN PAYLOAD The LoRAWAN messages in Uplink and Downlink are structured into a defined format in order to recognize them from LoRaWAN gateway side and to understand to which Modbus TCP requests they are associated.
  • Page 26: Mechanical Dimensions

    User Manual LoRaWAN / Modbus TCP Master Document code: MN67D03_ENG Revision 1.000 Page 26 of 29 Industrial Electronic Devices MECHANICAL DIMENSIONS: Figure 8: Mechanical dimensions scheme for HD67D03-B2 ADFweb.com S.r.l.
  • Page 27: Ordering Informations

    Enclosure Type B: Modulbox 2M, 35mm DIN Rail mounting Device Family HD67D03: LoRaWAN / Modbus TCP Master - Converter Order Code: HD67D03-B2-868MHz LoRaWAN / Modbus TCP Master – Converter ACCESSORIES: Order Code: AC34011 35mm Rail DIN - Power Supply 220/240V AC 50/60Hz – 12 V DC Order Code: AC34012 35mm Rail DIN - Power Supply 220/240V AC 50/60Hz –...
  • Page 28: Disclaimer

    User Manual LoRaWAN / Modbus TCP Master Document code: MN67D03_ENG Revision 1.000 Page 28 of 29 Industrial Electronic Devices DISCLAIMER: All technical content within this document can be modified without notice. The content of the document is a under continual renewal. For losses due to fire, earthquake, third party access or other accidents, or intentional or accidental abuse, misuse, or use under abnormal conditions repairs are charged to the user.
  • Page 29: Warranties And Technical Support

    User Manual LoRaWAN / Modbus TCP Master Document code: MN67D03_ENG Revision 1.000 Page 29 of 29 Industrial Electronic Devices WARRANTIES AND TECHNICAL SUPPORT: For fast and easy technical support for your ADFweb.com SRL products, consult our internet support at www.adfweb.com. Otherwise contact us at the address support@adfweb.com RETURN POLICY: If while using your product you have any problem and you wish to exchange or repair it, please do the following:...

Table of Contents