GE Profile JS998SKSS Installation Instructions Manual page 8

Self-cleaning radiant trivection electric slide-in range
Table of Contents

Advertisement

ELECTRICAL CONNECTIONS
3-WIRE POWER CORD
4
INSTALLATION
WARNING:
ground wire of the power cord must be
connected to the neutral terminal located
in the center of the terminal block. The
power leads must be connected to the
lower left and the lower right terminals
of the terminal block.
Remove the 3 lower terminal screws from
A
the terminal block. Insert the 3 terminal
screws through each power cord terminal
ring and into the lower terminals of the
terminal block. Be certain that the center
wire (white/neutral) is connected to the
center lower position of the terminal
block. Tighten screws securely into the
terminal block.
DO NOT remove the ground strap
connection.
Ground
plate
Power cord
Skip to Step 8 and proceed with the
B
installation.
Installation Instructions
The neutral or
Terminal
block
(appearance
may vary)
Neutral
terminal
Ground
strap
(cont.)
4-WIRE POWER CORD
5
INSTALLATION
WARNING:
the supply circuit must be connected to
the neutral terminal located in the lower
center of the terminal block. The power
leads must be connected to the lower
left and the lower right terminals of the
terminal block. The 4th grounding lead
must be connected to the frame of the
range with the ground plate and the
ground screw.
A
Remove the 3 lower terminal screws from
the terminal block. Remove the ground
screw and ground plate and retain them.
Cut and discard the ground strap. DO
B
NOT DISCARD ANY SCREWS.
C
Insert the one ground screw into the
power cord ground wire terminal ring,
through the ground plate and into the
frame of the range.
D
Insert the 3 terminal screws (removed
earlier) through each power cord terminal
ring and into the lower terminals of the
terminal block. Be certain that the center
wire (white/neutral) is connected to the
center lower position of the terminal
block. Tighten screws securely into the
terminal block.
Before
Terminal
block
Ground
strap
After
Terminal
block
Ground
screw
E
Skip to Step 8 and proceed with the
installation.
8
The neutral wire of
Ground strap
or
Neutral
terminal
Ground
plate
(grounding
to range)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Js998

Table of Contents