IBM RS/6000 7046 Service Manual page 80

Hide thumbs Also See for RS/6000 7046:
Table of Contents

Advertisement

Checkpoint
Description
(hex)
E122
No memory
detected (system
lockup) Note:
Harddisk light is on
continuously
E123
No SIMM found in
the socket
E124
Disable defective
memory bank
E125
Clear PCI devices
command reg, go
forth
E126
Check valid image -
start
E127
Check valid image -
successful
E128
Disable interrupts,
set int vectors for
O.F.
E129
Validate target RAM
address
E12A
Copy ROM to RAM,
flush cache
E12B
Set MP operational
parameters (eg.
L.E.?, Real?)
E12C
Set MP CPU node
characteristics
E12D
Park secondary
processors in
parking lot
E12E
Primary processor
sync
E12F
Unexpected return
from Open Firmware
(system lockup)
E130
Build device tree
E131
Create ROOT node
E132
Create CPUs node
3-16
7046 Model B50 Service Guide
All manuals and user guides at all-guides.com
Repair Action
1. Replace memory dimm(s)
2. Replace System Planar
3. Replace System Planar
See "Unresolved problems" on page 3-26
See "Unresolved problems" on page 3-26
See "Unresolved problems" on page 3-26
See "Unresolved problems" on page 3-26
See "Unresolved problems" on page 3-26
See "Unresolved problems" on page 3-26
See "Unresolved problems" on page 3-26
See "Unresolved problems" on page 3-26
See "Unresolved problems" on page 3-26
See "Unresolved problems" on page 3-26
See "Unresolved problems" on page 3-26
See "Unresolved problems" on page 3-26
See "Unresolved problems" on page 3-26
See "Unresolved problems" on page 3-26
See "Unresolved problems" on page 3-26
See "Unresolved problems" on page 3-26
See "Unresolved problems" on page 3-26