IBM RS/6000 7046 Service Manual page 70

Hide thumbs Also See for RS/6000 7046:
Table of Contents

Advertisement

Error Code
Function
/Description
25000xxx
Memory Controller
problem
25000000
Memory controller
failed
25010xxx
Flash Update
problem
25010000
No diskette in drive.
25010001
Diskette seek error.
25010002
Diskette in drive
does not contain an
*.IMG file.
25010003
Cannot open
OPENPROM
package.
25010004
Cannot find
OPENPROM node.
25010006
System ID does not
match image system
ID.
25010007
Image has bad
CRC.
25010008
Flash is write
protected, update
cancelled.
25010009
Flash module is
unsupported or not
recognized.
2501000A
Flash write
protected.
3-6
7046 Model B50 Service Guide
All manuals and user guides at all-guides.com
Repair Action/Possible Failing FRU
Replace system board (see note 3 on page 2-1).
Insert diskette containing firmware update file.
1. Retry function.
2. Replace diskette drive.
3. Replace diskette cable.
4. Replace system board (see note 3 on page 2-1).
Insert diskette with firmware update file
Replace system board (see note 3 on page 2-1).
Replace system board (see note 3 on page 2-1).
Make sure correct firmware update diskette is being
used with this system.
Replace firmware update diskette.
1. Turn off, then turn on the server and retry.
2. Replace system board (see note 3 on page 2-1).
Make sure correct firmware update diskette is being
used with this system.
1. Turn off, then turn on the server and retry.
2. Replace system board (see note 3 on page 2-1).