Gas Supply:
Power
• The natural gas models are designed to
Supply
operate at 6" to 14" water column pressure.
• The liquid propane models are designed to
Locations
operate at 11 to 14" water column pressure.
A regulator is required at the L.P. source to
provide a maximum of 14" water pressure to
the range regulator.
• These gas ranges are supplied with 1/2"
NPT female gas connection located at the
left rear corner.
• A minimum 5/8" dia. metal flexible line is
required.
• For flexible connection, locate pipe stub on
the back wall as illustrated.
— Use 5-foot, 5/8" long flexible gas supply
line.
• For rigid connection, locate the pipe stub as
illustrated.
• Install a manual shut-off valve in the gas
line, in an easily accessible location.
Electric Supply:
These ranges must be supplied with 208/240
volt, 60 Hz., and connected to an individual,
properly grounded branch circuit protected
by a circuit breaker or time delay fuse (50
amp for 48" ranges, 30 amp for 36" ranges
and 25 amps for 30" ranges). The receptacle
must be a NEMA 14-50R devise to accept the
4-prong plug supplied with the range.
The range is equipped for use with an
electrical supply which uses a separate
grounding conductor (4 wire system).
If this range must be connected to an
electrical system which utilizes a single
conductor for ground and neutral (3 wire
system), the grounding jumper at the
terminal block must be connected. The
grounding jumper is located behind the
front kick panel.
CAUTION
WARNING

Installation Preparation

Professional Ranges
4" For 30"/36" Models
8" For 48" Models
12"
Flex Line
Gas Supply
to Range
2" Maximum
Protrusion From
Wall For Gas
Supply
If the electrical service provided does not
meet the above specifications, it is recom-
mended that a licensed electrician install an
approved outlet.
• Locate the electric supply as illustrated.
Green
Connect Here
Terminal Block
To connect grounding jumper:
• Disconnect restraining clip holding jumper.
• Connect green jumper to open terminal on
neutral (white) portion of the terminal
block.
12" For 30"/36" Models
16" For 48" Models
Electrical
Supply
3-1/4"
NEMA 14-50R
Receptacle
3-1/2"
Red
White
Black
7