Change setting continued
The function of the potential free
Multi
multi- function relay output on
terminal 5/6 can be defined as follows.
funct.
The table describes the required
output
function, when the output is activated,
that means when the relay contact is
8
closed.
Setting value
0
1
2
3
4
5
6
7
8
9
10
11
12
Setting of weekday and time.
Day/
The DHW, legionella and circulation
program is activated by the time.
Time
The time also activates the pump
standby protection and the reset of the
maximum collector temperature.
Tues 15:00
Heat exchanger
Special temperature level
interlock / release
heat exchanger for
tank loading
leginonella function
interlock
release
interlock
release
Setting range
Heat exchanger
interlock / release
calorifier loading
interlock
release
interlock
interlock
Variation: 1...84
1...8 Heat exchanger release/interlock
( Ch. 7.2, 7.13, 7.14)
9...10 Lockout signalling
( Ch. 7.3)
11...12 Excess temperature relief
( Ch. 7.1)
Additional
functions
release
release
lockout
no lockout
Excess temperature
Excess temperature
relief inverse
6
relief
67