Selection menu
A selection menu only has text and no dotted line. The sub
menu is reached by pressing the
exit, any changes not saved are lost.
Sub menu
A sub menu has a dotted line in the centre of the display.
By pressing the
the selected parameter for taking over
into the standard display can be selected, or made
adjustable. The adjustable value flashes.
The change has to be confirmed by pressing the
to save the new value. If the
previous value is re-entered.
Display does not show standard display
If the display shows the display to the right when voltage is
applied, the display is not started correctly. Pressing the
reset key re-initialises the display and the standard display
is shown.
If the standard display does not appear after repeated
initialisation the controller should be replaced.
Resetting the display
The display and all parameter are reset to the factory
settings by activating the factory presettings in menu
Select options.
, pressing
means
esc
key
key is pressed the
esc
Selection menu
Select
temp. and
values
Sub menu
Collect.
temp.
minimum
20°C
Collect.
temp.
minimum
20°C
Display not initialised
Standard display
TKO
67°C
TSU
49°C
PS
100%
BA
Auto
5
51