8.4

Recommendations

8.4.1

Use original spare parts

Caution - material
Risk of damage due to use of non-genuine spare parts !
To ensure correct operation and safety of the device, only use original spare parts and
accessories recommended by the manufacturer.
Usage of non-genuine spare parts voids all warranties.
Parts to keep in stock for potential replacements are motor and optical sensor, controller,
transformer, injectors, flapper kit, o-ring kit, refill controller and DLFC.
8.4.2

Use original approved lubricants

• Production:
p/n 1014082 (NFO "Chemplex" 862 Silicone Comp.);
• spare part:
p/n 42561 (SILICONE LUBRICANT PACK).
8.5

Cleaning and maintenance

8.5.1

First steps

Before any cleaning or maintenance procedure, complete the following steps:
Mandatory
These operations must be performed before any cleaning or maintenance procedure !
1. Unplug the wall-mounted transformer.
2. Shut off water supply or put bypass valve(s) into bypass position.
3. Relieve system pressure before performing any operations.
Ref. MKT-IM-037 / D - 25.10.2021