Welcome
This guide will help you start with monitoring using the
VistaPoint
application and the VitalPatch
™
The VitalPatch biosensor (referred to as "VitalPatch" in
this document) is an adhesive device worn on the chest
to measure and record vital signs. Refer to the VitalPatch
Instructions for Use (IFU-10-EUA) for detailed clinical
instructions.
The VistaPoint application collects and uploads vital
signs from the VitalPatch and approved third-party
devices to your care team. VistaPoint runs on the
portable VistaTablet
device.
™
VitalPatch
VistaPoint on VistaTablet
Contents
Getting Started
Monitoring Using VistaPoint
Entering Vital Signs Manually
Oxygen Saturation. . . . . . . . . . . . . . . . . . . . . . . . . . 13
Blood Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Uploading Vital Signs Using Bluetooth
Oxygen Saturation (Berry BM1000/BM2000A) . . . . 14
Blood Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
. . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
IFU-20 Rev. 04 (February 2021)
WARNING: The arrhythmia detection
features in this product have not received
FDA clearance for patient care.
Indications for Use
Contraindications (When not to use)
biosensor.
®
Do not use the VistaPoint application as a standalone
diagnostic monitor. However, the data may be applicable
for use in diagnosis.
VistaPoint is a software Graphical User Interface
intended for use by healthcare professionals to display
physiological data collected by the Vista Solution
wireless remote monitoring system in home and
healthcare settings. VistaPoint is a secondary, adjunct
patient monitor and is not intended to replace existing
standard-of-care patient monitoring practices.
Arrhythmia Detection Precautions
The following precautions apply only when using the
optional VitalPatch arrhythmia detection feature and the
VitalPatch described in VitalPatch Instructions for Use
(IFU-10-EUA). If other models of VitalPatch are used,
arrhythmia detection will not be available.
Care Team
• Apply the VitalPatch in the Primary (upper) position
• The VistaPoint application does not provide indication
Pacemaker Precautions
The following precautions apply only when using the
VitalPatch described in VitalPatch Instructions for Use
(IFU-10-EUA) or VitalPatch Instructions for Use (IFU-06).
• The VitalPatch may be used on patients with
VistaPoint Precautions
• Invalid posture data (shown as "?") indicates a
• Body movements and contact with the VitalPatch
• After applying VitalPatch, it may take 60 seconds for
• After applying VitalPatch, it may take several minutes
VistaPoint 3.0 QuickStart
and Instructions for Use
only. If the Secondary (lower) position is used, the
VitalPatch will not operate and must be replaced.
of arrhythmia events detected by VitalPatch. If
arrhythmia detection is enabled, detected events are
transmitted to your care team for analysis.
pacemakers. However, ECG data, heart rate, and
respiration rate will not be measured and displayed if
a pacemaker is indicated as present.
non-calibrated state where respiration rate, posture,
and fall data are considered invalid.
may produce motion artifacts that affect the
displayed, measured values for ECG and heart rate.
heart rate to stabilize and respiration rate 180
seconds to stabilize. During the stabilization period
VistaPoint will display "--" for those vital signs.
for skin temperature to register an accurate value (for
VitalPatch with firmware 1.0.4.x).
1