Advertisement

Quick Links

Contents
Welcome . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Indications for Use . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Getting Started
Setting Up VistaTablet or VistaPhone . . . . . . . . . . . . 2
Viewing and Changing Device Name. . . . . . . . . . . . . 3
Removing Previous VitalPatch. . . . . . . . . . . . . . . . . . 4
Applying the VitalPatch . . . . . . . . . . . . . . . . . . . . . . . 4
Wearing the VitalPatch. . . . . . . . . . . . . . . . . . . . . . . . 5
Applying the Adhesive Overlay . . . . . . . . . . . . . . . . . 6
Monitoring Using VistaPoint
Pairing VitalPatch with VistaPoint . . . . . . . . . . . . . . . 7
Using the VistaPoint Dashboard . . . . . . . . . . . . . . . . 9
When Monitoring is Complete . . . . . . . . . . . . . . . . . 11
Reporting a Symptom . . . . . . . . . . . . . . . . . . . . . . . 11
Making a Video Call or Appointment . . . . . . . . . . . 11
Routine Events During Monitoring . . . . . . . . . . . . . . 12
Entering Body Temperature Manually . . . . . . . . . . . 14
Changing Pacemaker Status . . . . . . . . . . . . . . . . . . 14
Entering Vital Signs Manually
Oxygen Saturation. . . . . . . . . . . . . . . . . . . . . . . . . . 15
Blood Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Oxygen Saturation (Nonin 3150) . . . . . . . . . . . . . . . 20
Oxygen Saturation (Nonin 3230) . . . . . . . . . . . . . . . 22
Blood Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
. . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Getting Help
Tap the Menu button in the upper-right corner of the
screen and then tap Help. You can read instructional
documents or watch tutorial videos.
Press the Home button to return to monitoring.
IFU-26 Rev. D
VistaPoint 3.1 QuickStart
and Instructions for Use

Welcome

This guide will help you start monitoring using the
VistaPoint
and the VitalPatch
The VitalPatch biosensor (referred to as "VitalPatch" in
this document) is an adhesive device worn on the chest
to measure and record vital signs. Refer to the VitalPatch
Instructions for Use for detailed clinical instructions.
The VistaPoint application collects and uploads vital
signs from the VitalPatch and approved third-party
devices to your care team. VistaPoint runs on the
portable VistaTablet
or VistaPhone
VitalPatch
VistaPoint on VistaTablet
VitalPatch
VistaPoint on VistaPhone

Indications for Use

Contraindications (When not to use)
Do not use the VistaPoint application as a standalone
diagnostic monitor. However, the data may be applicable
for use in diagnosis.
VistaPoint is a software Graphical User Interface
intended for use by healthcare professionals to display
physiological data collected by the Vista Solution
wireless remote monitoring system in home and
healthcare settings. VistaPoint is a secondary, adjunct
patient monitor and is not intended to replace existing
standard-of-care patient monitoring practices.
Pacemaker Precautions
The following precaution applies when using the
VitalPatch described in VitalPatch Instructions for Use
(IFU-06): "The VitalPatch may be used on patients with
pacemakers. However, ECG data, heart rate, and
respiration rate will not be measured and displayed if a
pacemaker is indicated as present."
biosensor.
®
device.
Care Team
Care Team
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VistaPoint 3.1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for VitalConnect VistaPoint 3.1

  • Page 1: Table Of Contents

    VistaPoint 3.1 QuickStart and Instructions for Use Contents Welcome This guide will help you start monitoring using the Welcome ........1...
  • Page 2: Setting Up Vistatablet Or Vistaphone

    VistaPoint Precautions • After applying VitalPatch, it may take 60 seconds for • Invalid posture data (shown as “?”) indicates a heart rate to stabilize and respiration rate 180 non-calibrated state where respiration rate, posture, seconds to stabilize. During the stabilization period and fall data are considered invalid.
  • Page 3: Checking Device Battery Level And Patch Hours

    Section 2: Checking Device Battery Level and VitalPatch Hours Checking Device Battery Level VistaTablet VitalPatch Hours VistaTablet Battery Level To check the VistaTablet or VistaPhone battery level, look at the battery indicator in the status bar (see figure to the right. Do not let the battery run out.
  • Page 4: Removing Previous Vitalpatch

    Grasp a corner of the overlay and peel it off the skin. b. Continue pulling the overlay off. Stretch the overlay VitalConnect horizontally to help release it from the skin. Note: The VitalPatch may begin pulling off with the overlay.
  • Page 5: Wearing The Vitalpatch

    2. Power-On VitalPatch a. Place VitalPatch on a flat surface. VitalConnect b. Press and release the power button. See figure to the right. A green light below the logo flash to let you know the VitalPatch is powered on (the light will not stay illuminated).
  • Page 6: Applying The Adhesive Overlay

    VitalPatch should be aligned with the cutouts of the overlay. See figure to the right. VitalConnect b. Ensure the tab you created in the previous step is on the top side (pointing towards your head).
  • Page 7: Pairing Vitalpatch With Vistapoint

    Section 8: Pairing VitalPatch with VistaPoint 1. Begin the Pairing Process Section 1 on Unlock the VistaTablet or VistaPhone (see Page Tap Connect VitalPatch from the VistaPoint dashboard. Connect VitalPatch If a previous VitalPatch is still connected, disconnect it Section 10 on Page 11).
  • Page 8 5. Posture Calibration — Body Position Select the body position: Select Body Position • Standing or Sitting (preferred) — Patient must sit as upright as physically capable. Posture Calibration • Supine — Patient must lie down in a supine position Step 2 Select Current Body Position as flat as physically capable.
  • Page 9: Using The Vistapoint Dashboard

    Section 9: Using the VistaPoint Dashboard VistaTablet Main Menu Report Symptom Menu VistaPoint ™ Posture VitalPatch Heart Rate Posture Report a Symptom 109 hours Heart Rate VitalPatch ID b008bf_012792 has remaining See Section 11 Live ECG Upright Fall Detection 2 mv VitalPatch Respiration Rate Fall Detection...
  • Page 10 • Verify correct display of vital signs and verify the • Discharge Patient: End monitoring session and displayed posture matches the patient’s posture. disconnect all devices. Use only as directed. • To refresh the view, swipe the screen from top to • About VistaPoint: Show information about the bottom.
  • Page 11: When Monitoring Is Complete

    Section 10: When Monitoring is Complete 1. Disconnect VitalPatch in VistaPoint Menu When monitoring is complete, select Disconnect VitalPatch from the menu. Select one of the following Tap “Disconnect Disconnect Patch options: Patch” • Disconnect VitalPatch: Choose this option if you will be applying a new VitalPatch.
  • Page 12: Routine Events During Monitoring

    Section 13: Routine Events During Monitoring Message: “VitalPatch Off Body” Indicates that the VitalPatch detects that it was removed. VitalPatch b008bf_012345 Off Body • If removal was intentional, tap Disconnect Patch to Check that the VitalPatch biosensor is properly adhered to the skin. end the monitoring session.
  • Page 13 Message: “VitalPatch Not Detected” VitalPatch b008bf_012345 Not Detected Indicates that the VitalPatch is out of range, has lost If the Patch is Out of Range If the Patch Has Been Removed Bluetooth connection, or has expired. • If disconnection was intentional or VitalPatch has expired, tap Disconnect Patch to end the monitoring Make sure the VitalPatch is in range.
  • Page 14: Recalibrating Automatic Body Temperature

    Menu Section 14: Recalibrating Automatic Body Temperature Disconnect Patch When using the automatic body temperature feature, you Calibrate Posture Menu should recalibrate body temperature each day between Calibrate Temperature the hours of 09:00 and 21:00. The VistaPoint dashboard Disconnect Patch may also prompt you to recalibrate the body temperature Flash Patch LED Calibrate Posture...
  • Page 15: Oxygen Saturation

    Section 17: Entering Oxygen Saturation Manually This procedure is for manual entry only. If you are performing Begin Manual Entry automatic entry with a paired Bluetooth device, refer to Section 23 on page 22 Section 22 on page 20 (for Nonin 3230) or (for Take SPO2 Tap Take SpO2 or...
  • Page 16: Uploading Vital Signs Using Bluetooth Oxygen Saturation (Berry Bm1000/Bm2000A)

    Section 20: Using Bluetooth to Upload Oxygen Saturation (Berry BM1000 or BM2000A) NOTE: If the device has already been paired, go directly Step 3 “Take A Reading” below. The Berry BM1000 and BM2000A are optional pulse oximeter devices that measure blood oxygen saturation (%SpO ) and upload readings automatically using Bluetooth.
  • Page 17 2. Pair New in VistaPoint See figure to the right. a. Apply the Berry BM1000 or the BM2000A to the previous page. finger. Power-on as described on the Pair Device or Take a Reading b. Tap Take SpO2 in the Oxygen Saturation tile Apply device to finger (or Take a Measurement on VistaPhone and then Take SpO2).
  • Page 18: Oxygen Saturation (Masimo Mightysat)

    Section 21: Using Bluetooth to Upload Oxygen Saturation (Masimo MightySat™ Fingertip) Masimo MightySat NOTE: If the device has already been paired, go directly Step 4 “Take A Reading” below. The Masimo MightySat™ is an optional pulse oximeter Masimo device that measures blood oxygen saturation (%SpO MightySat and uploads readings automatically using Bluetooth.
  • Page 19 3. Pair New in VistaPoint See figure to the right. a. Apply the Masimo MightySat to the finger. The device will automatically turn on and begin measuring. Pair Device or Take a Reading b. Tap Take SpO2 in the Oxygen Saturation tile (or Take Insert finger a Measurement on VistaPhone).
  • Page 20: Oxygen Saturation (Nonin 3150)

    Section 22: Using Bluetooth to Upload Oxygen Saturation (Nonin 3150 Wrist) NOTE: If the device has already been paired, go directly Nonin 3150 Pulse Oximeter Step 4 “Start Continuous Measurement” below. The Nonin Model 3150 is an optional pulse oximeter device that measures blood oxygen saturation (%SpO and uploads readings automatically using Bluetooth.
  • Page 21 3. Pair New in VistaPoint Pair Device or Take a Reading See figure to the right. • If pairing, place in pairing mode a. Put device in pairing mode (previous step). • If measuring, apply to wrist and fingertip b. Tap Take SpO2 in the Oxygen Saturation tile (or Take a Measurement on VistaPhone and then Take SpO2).
  • Page 22: Oxygen Saturation (Nonin 3230)

    Section 23: Using Bluetooth to Upload Oxygen Saturation (Nonin 3230 Fingertip) The Nonin Model 3230 is an optional pulse oximeter Nonin 3230 Pulse Oximeter device that measures blood oxygen saturation (%SpO and uploads readings automatically using Bluetooth. It is Apply to clipped onto your fingertip.
  • Page 23: Blood Pressure

    Section 24: Using a Bluetooth Device to Upload Blood Pressure A&D UA-651 NOTE: If the device has already been paired, go directly Step 4 “Take A Reading” below. Blood Pressure Cuff Model UA-651 Base Unit The A&D UA-651 is an optional blood pressure monitor that can upload blood pressure readings automatically using Bluetooth.
  • Page 24: Weight

    Section 25: Using a Bluetooth Device to Upload Weight NOTE: If the device has already been paired, go directly Step 3 “Take A Reading” below. The A&D UC-352 is an optional weight scale that can Press Label upload weight readings automatically using Bluetooth. SET Button Use as directed by your care team.
  • Page 25: Troubleshooting

    Section 26: Troubleshooting Message: Cloud Service Down Cloud Service Down If you see this message, it indicates that the cloud The cloud service is currently down. This service is not operational at this time. Tap OK to dismiss problem will be resolved soon. the message.