Setting Up VistaTablet . . . . . . . . . . . . . . . . . . . . . . . . 2
Removing Previous VitalPatch. . . . . . . . . . . . . . . . . . 3
Applying the VitalPatch . . . . . . . . . . . . . . . . . . . . . . . 3
Wearing the VitalPatch. . . . . . . . . . . . . . . . . . . . . . . . 4
Applying the Adhesive Overlay . . . . . . . . . . . . . . . . . 5
Monitoring Using VistaPoint
Pairing VitalPatch with VistaPoint . . . . . . . . . . . . . . . 6
Using the VistaPoint Dashboard . . . . . . . . . . . . . . . . 8
When Monitoring is Complete . . . . . . . . . . . . . . . . . . 9
Routine Events During Monitoring . . . . . . . . . . . . . . 10
Recalibrating Body Temperature . . . . . . . . . . . . . . . 12
Entering Vital Signs Manually
Oxygen Saturation. . . . . . . . . . . . . . . . . . . . . . . . . . 12
Blood Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Uploading Vital Signs Using Bluetooth Devices
Oxygen Saturation (Fingertip) . . . . . . . . . . . . . . . . . 14
Oxygen Saturation (Wrist) . . . . . . . . . . . . . . . . . . . . 15
Blood Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Indications for Use
Contraindications (When not to use)
Do not use the VistaPoint application as a
standalone diagnostic monitor. However, the data
may be applicable for use in diagnosis.
VistaPoint is a software Graphical User Interface
intended for use by healthcare professionals to
display physiological data collected by the Vista
Solution wireless remote monitoring system in home
and healthcare settings. VistaPoint is a secondary,
adjunct patient monitor and is not intended to replace
existing standard-of-care patient monitoring practices.
Refer to the VitalPatch Instructions for Use (IFU-02 or
IFU-06) for additional indications, warnings and
precautions.
IFU-15 Rev. A (September 2019)
VistaPoint 2.1 QuickStart
and Instructions for Use
Welcome
This guide will help you get started with monitoring
using the VistaPoint
application and the VitalPatch
biosensor.
The VitalPatch biosensor (referred to as "VitalPatch" in
this document) is an adhesive device worn on the
chest to measure and record vital signs. Refer to the
VitalPatch Instructions for Use (IFU-02 or IFU-06) for
detailed clinical instructions.
The VistaPoint application collects and uploads vital
signs from the VitalPatch and approved third-party
devices to your care team.
VistaPoint runs on the portable VistaTablet
VitalPatch
VistaPoint on VistaTablet
VistaPoint Precautions
• Invalid posture data (shown as "?") indicates a
non-calibrated state where respiration rate, posture,
and fall data are considered invalid.
• Body movements and contact with the VitalPatch
may produce motion artifacts that affect the
displayed, measured values for ECG and heart rate.
• After applying VitalPatch, it may take 45 seconds
for heart rate to stabilize and respiration rate 120
seconds to stabilize. During the stabilization period
VistaPoint will display "--" for those vital signs.
• After applying VitalPatch, it may take several
minutes for skin temperature to register an accurate
value (for VitalPatch with firmware 1.4.0.x).
®
device.
Care Team
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VistaPoint 2.1 and is the answer not in the manual?

Questions and answers

Summary of Contents for VitalConnect VistaPoint 2.1

  • Page 1: Table Of Contents

    VistaPoint 2.1 QuickStart and Instructions for Use Contents Welcome Getting Started This guide will help you get started with monitoring using the VistaPoint application and the VitalPatch ™ ® Setting Up VistaTablet ......2 biosensor.
  • Page 2: Setting Up Vistatablet

    Section 1: Setting Up VistaTablet Before you begin your monitoring session, unpack the VistaTablet device and become familiar with its parts. Keep the packaging that was provided with the Power Key Volume Up/Down Status Bar VistaTablet. Menu Identifying VistaTablet Parts Charging Become familiar with the parts of the VistaTablet Port...
  • Page 3: Removing Previous Vitalpatch

    Grasp a corner of the overlay and peel it off the skin. VitalConnect b. Continue pulling the overlay off. Stretch the overlay horizontally to help release it from the skin. Note: The VitalPatch may begin pulling off with the overlay.
  • Page 4: Wearing The Vitalpatch

    3. Hold VitalPatch Against Chest on Selected Site DO NOT remove the adhesive backings until Step 4! Hold the VitalPatch against the chest in the correct or SECONDARY). See figures below. position (PRIMARY PRIMARY Site SECONDARY Site LEFT Side LEFT Side (Recommended) This site is not a.
  • Page 5: Applying The Adhesive Overlay

    See figure to the right. b. Ensure the tab you created in the previous step is on the top side (pointing towards your head). VitalConnect 4. Remove Blue Liners a. Hold the overlay against your chest with one hand and peel away the lower blue liner.
  • Page 6: Pairing Vitalpatch With Vistapoint

    Section 7: Pairing VitalPatch with VistaPoint 1. Unlock VistaTablet Enter PIN If the VistaTablet is asleep (black screen), unlock and Home Key start the VistaPoint application: a. Press the Home Key on the VistaTablet. SWIPE b. Swipe finger across the screen and enter the PIN provided by your care team.
  • Page 7 6. Posture Calibration — Body Position Select Body Position Select the body position: Posture Calibration Step 2 Select Current Body Position • Standing or Sitting (preferred) — Patient must sit as upright as physically capable. • Supine — Patient must lie down in a supine position Standing or Sitting Elevated Supine...
  • Page 8: Using The Vistapoint Dashboard

    Section 8: Using the VistaPoint Dashboard VitalPatch VitalPatch ID Hours Remaining VistaTablet Battery Life Main Menu Menu VistaPoint ™ Heart Rate Posture VitalPatch Heart Rate VitalPatch ID b008bf_012792 has 109 hours remaining. Upright Live ECG Current Posture 2 mv Respiration Rate Fall Detection BrPM Live ECG from...
  • Page 9: When Monitoring Is Complete

    Main Menu The Menu is in the top-right corner of the dashboard. It Menu has the following options: • Disconnect Patch: Use when monitoring is complete Disconnect Patch or to pair a new VitalPatch. This option maintains Recalibrate posture the pairing with third-party devices. Calibrate Posture •...
  • Page 10: Routine Events During Monitoring

    Section 10: Routine Events During Monitoring Message: “VitalPatch Off Body” Indicates that the VitalPatch detects that it was VitalPatch b008bf_012345 Off Body removed. Check that the VitalPatch biosensor is properly adhered to the skin. • If removal was intentional, tap Disconnect Patch to If the VitalPatch is okay, select “Wait If the VitalPatch has been removed end the monitoring session.
  • Page 11 Message: “VitalPatch Not Detected” VitalPatch b008bf_012345 Not Detected Indicates that the VitalPatch is out of range and/or has If the Patch is Out of Range If the Patch Has Been Removed lost Bluetooth connection. • If disconnection was intentional, tap Disconnect Make sure the VitalPatch is in range.
  • Page 12: Recalibrating Body Temperature

    Section 11: Recalibrating Body Temperature When using a VitalPatch that supports the body Menu temperature feature, you should recalibrate body Disconnect Patch temperature each day between the hours of 09:00 and 21:00. The VistaPoint dashboard may also prompt you Calibrate Posture to recalibrate the body temperature as necessary.
  • Page 13: Blood Pressure

    Section 13: Entering Blood Pressure Manually This procedure is for manual entry only. If you are performing automatic entry with a paired Bluetooth Begin Manual Entry Section 17 on page device, refer to Tap Take BP Take BP 1. Use a blood pressure device to measure your blood pressure.
  • Page 14: Oxygen Saturation (Fingertip)

    Section 15: Using a Bluetooth Device to Upload Oxygen Saturation (Fingertip) NOTE: If the device has already been paired, go directly Step 3 “Take A Reading” below. Apply to Finger The Nonin Model 3230 is an optional pulse oximeter device that measures blood oxygen saturation (%SpO ) and uploads readings automatically using Bluetooth.
  • Page 15: Oxygen Saturation (Wrist)

    3. Take a Reading (After Pairing) Take a Reading a. Tap Take SpO2 in the Oxygen Saturation tile. Take SPO2 b. Tap Use Bluetooth (if not already selected). c. Tap Take Reading. Take Reading d. Apply the Model 3230 to the finger. The unit will automatically turn on and being measuring.
  • Page 16 Begin Pairing 3. Pair New in VistaPoint Take SPO2 a. Put device in pairing mode (previous step). Tap Use Bluetooth b. Tap Take SpO2 in the Oxygen Saturation tile. c. Tap Use Bluetooth. Take Oxygen Saturation d. Tap Pair New. Manual Entry Use Bluetooth e.
  • Page 17: Blood Pressure

    Section 17: Using a Bluetooth Device to Upload Blood Pressure Blood Pressure Cuff NOTE: If the device has already been paired, go directly Model UA-651 Base Unit Step 4 “Take A Reading” below. The A&D UA-651 is an optional blood pressure monitor that can upload blood pressure readings automatically using Bluetooth.
  • Page 18: Weight

    Section 18: Using a Bluetooth Device to Upload Weight NOTE: If the device has already been paired, go directly Step 3 “Take A Reading” below. The A&D UC-352 is an optional weight scale that can Press Label upload weight readings automatically using Bluetooth. SET Button Use as directed by your care team.
  • Page 19: Troubleshooting

    Section 19: Troubleshooting Message: Cloud Service Down Cloud Service Down If you see this message, it indicates that the cloud service is not operational at this time. Tap OK to The cloud service is currently down. This problem will be resolved soon. dismiss the message.
  • Page 20 VitalConnect, Inc. 224 Airport Parkway, Suite 300, San Jose, CA 95110 | (408) 963-4600 | www.vitalconnect.com | support@vitalconnect.com © 2019 VitalConnect. A list of our trademarks can be found at www.vitalconnect.com. All other marks may be trademarks of their respective companies.

Table of Contents