Calibration Error Messages ..............21 Serial Communication ....................22 Scale Status Byte Definition ................24 Appendix A: Available PC-820 Displays ..............25 Appendix B: Tips on Using Harmonizer ..............27 Technical Drawings and Parts Lists ..............29-46 10 lb / 5 kg 12" x 14" Parts and Assembly ............29 Draft Shield Parts and Assembly ................
Zero, Low Battery, Unit of Measure and Display Label Display 240 x 64 dot matrix LCD display 5" x 1.33" displayable area PC-820: Cold cathode fluorescent backlit (white on blue) PC-821: LCD without backlight Display rate Selectable update rate: 0.5, 1, 2, or 5 times per second...
SimPoser. PC-820 Description The PC-820 is a 12” x 14” scale with an attached 5” x 12” display housing. To increase the contrast of the ® See Figure 1. The scale base is cast aluminum enclosing a Quartzell display, press and hold the weight sensor and electronics package.
The keys on the front panel of the PC-820 are of two types; hard keys and Front Panel Keys softkeys. Hard keys are labeled directly and softkey labels appear on the display. Softkeys function differently at different times and their labels change as needed.
See Figure 4 and the Setup Menu section below for more infor- mation. Press this softkey to turn the PC-820 off. Pressing any key will turn the scale on. The Test menu, shown in Figure 3, lets you test your scale operation.
Page 8
Inputs Softkey Inputs The same as Outputs except you are activating an input set- point device such as a switch or contact closure remotely and monitoring it with this menu. PC-820/821 Parts Counter Service Manual...
4 = Max 5 = ROC 6 = Gross total 7 = Net total 8 = Count total 9 = Transaction total 10 = Count 11 = Variable 12 = Piece weight 13 = ADC PC-820/821 Parts Counter Service Manual...
Page 10
Figure 4a Setup Menus PC-820/821 Parts Counter Service Manual...
Page 11
Press Select: The following softkeys are displayed: Display You are prompted to enter a display mode number (1-20). See Appendix A: Available PC-820 Displays. Base You are asked to pick the active scale base. Only active bases are offered as choices.
The first softkey under Scale is # Bases. Press this and you are prompted to key in the number of remote bases (0-2) attached to the PC-820. Remote 1 is Quartzell by default. You can set Remote 1 to work with an analog base.
Page 13
• Latch = Count filter and sample latching mode: Count filter: You can choose a count filter of OFF, Fast or Slow. (Default is Fast). The count filter, which can also be called count latching, PC-820/821 Parts Counter Service Manual...
Page 14
If the All these keys can be enabled by the firmware in the PC-820, but the BASIC application in the PC-820 will need additional code for these keys to func- remote base softkey is en- tion.
Page 15
Y/M/D = Year/Month/Day Default is M/D/Y. Print Fm Softkey Press the Print Fm softkey to configure the port to use for each print format. First you choose the default print format. Choices are from 0-32. Default is PC-820/821 Parts Counter Service Manual...
Page 16
The indicator will repeat removing ½ the weight every X seconds. X being the number of seconds you have picked. Default is 0.5 division and 1 second. Set division size to zero to disable AZT. PC-820/821 Parts Counter Service Manual...
Page 17
The PC-820 samples the Quartzell at 50 times per second (60 times per second for external Quartzells and analog bases). If ROC Samples is set to 50, the PC-820 is determining the rate of weight change over one full second.
Page 18
• Tare timeout • Sample timeout Timeout is the amount of time the PC-820 will wait for motion to cease and perform the function after the key is pressed. For example, if Zero Timeout is set to 3 seconds, when the ZERO key is pressed the unit will zero the scale if there is no motion.
Page 19
YES the unit defaults to an interval size of one half of capacity. You can key in any interval size you want. After entering the interval size you are prompted to enter the division size for the interval. Key this in and press ENTER. PC-820/821 Parts Counter Service Manual...
2. Press the SETUP softkey. . . Scale prompts for a password. 3. Key in 30456 and press ENTER. . . You are then given the choice of Local, Remote 1 or Remote 2. PC-820/821 Parts Counter Service Manual...
QDT base. Verify correct cable connections, then setup the capacity and division size in the calibration menu. This forces the PC-820 to scan the QDT cell for its serial number and that may be viewed in the Test menu.
No conn. No connection. Table 1 Port 1 (Com 1) pin outs Com 2 is a 15 pin DE type connector at the rear of the PC-820. The func- tional pin out is as follows: PIN NO. SIGNAL NAME DEVICE USED WITH...
Page 23
<CR> ASCII carriage return character hours minutes represents the three bytes of scale status AM or PM information as described on the next day of week page. day of month year Table 3 Computer commands and responses PC-820/821 Parts Counter Service Manual...
If the Threshld value is too high your scale will react slowly to weight changes. When Harmonizer is properly adjusted the scale will be stable at zero and will rapidly display a stable test weight value. PC-820/821 Parts Counter Service Manual...
Page 28
PC-820/821 Parts Counter Service Manual...
PC-820/821 COUNTING SCALE DRAFT SHIELD (optional) (10 lb./ 5 kg 12” x 14” base only) PARTS AND ASSEMBLY ITEM DESCRIPTION W-T P/N SUPPORT POST 1058-15413 SHIELD DOOR 1069-15404 SHIELD TOP PANEL 1069-15403 SHIELD REAR PANEL 1069-15406 SHIELD SIDE PANEL 1069-14604...
PC-820/821 COUNTING SCALE SYSTEM WIRING BLOCK DIAGRAM NOTE: For remote base wiring information Ref. The “Bench Scale Bases” installation manual (P/N 16783-0017) shipped with your base. PIN NO. ANALOG SIGNAL -SIGNAL COM 2 (J9) +SIGNAL +EXCITATION SIGNAL DEVICE PIN NO.
OPTO-22 CONTROL INTERFACE DEVICES Specifications The OPTO-22 Generation 4 I/O modules can be used on the optional Remote Expanded Control Interface Boards (max. 32). OPTO-22 I/O Type External circuit External Turn on Turn off I/O operating AC or DC Color voltage range circuit time msec.
Page 47
This declaration becomes valid when the SMA Conformance Logo, having our name or trade- mark is applied to the device or its accompanying documentation. * SMA PRODUCTION MEETS TYPE DEVICE MANUFACTURER Conformance Logo and Design are a registered trademark of the Scale Manufacturers Association PC-820/821 Parts Counter Service Manual...