7. Reconnect the power supply cord after the rear cover and the outer case are installed.
8. Run the oven and check all functions.
NOTE: If the door sensing switch contacts fail in the open position and the door is closed, the blower motor, stirrer motors and oven light will be acti-
vated by RY1.
2. PRIMARY INTERLOCK RELAY RY1
1. Disconnect the power supply cord, and then remove outer case and rear cabinet.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Disconnect two (2) wire leads from the male tab terminals of the Primary Interlock Relay RY1. Check the state of the relay contacts using a ohm-
meter. The relay contacts should be open. If the relay contacts are closed, replace the circuit board entirely or the relay itself.
5. Reconnect all leads removed from components during testing.
6. Reinstall the rear cover and the outer case (cabinet).
7. Reconnect the power supply cord after the rear cover and the outer case are installed.
8. Run the oven and check all functions.

[7] G: MONITOR SWITCH (1) AND/OR (2) TEST

1. Disconnect the power supply cord, and then remove outer case and rear cabinet.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Before performing this test, make sure that the secondary interlock switches (1), (2) and the primary interlock relay RY1 are operating properly,
according to the above Switch Test Procedure. Disconnect the wire lead from the monitor switches (1), (2) (COM) terminals. Check the monitor
switches (1), (2) operation by using the ohmmeter as follows. When the door is open, the meter should indicate a closed circuit. When the monitor
switch actuator is pushed by a screw driver through the upper latch hole on the front plate of the oven cavity with the door opened (in this condition
the plunger of the monitor switch is pushed in), the meter should indicate an open circuit. If improper operation is indicated, the switch may be
defective. After testing the monitor switches, reconnect the wire lead to the monitor switch (COM) terminals and check the continuity of the monitor
circuit.
5. Reconnect all leads removed from components during testing.
6. Reinstall the rear cover and the outer case (cabinet).
7. Reconnect the power supply cord after the rear cover and the outer case are installed.
8. Run the oven and check all functions.

[8] H: BLOWN MINITOR FUSE TEST

1. Disconnect the power supply cord, and then remove outer case and rear cabinet.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. If the monitor fuse is blown when the door is opened, check the primary interlock relay RY1, secondary interlock switches (1), (2) and monitor
switches (1), (2) according to the "TEST PROCEDURE" for those switches before replacing the blown monitor fuse.
CAUTION: CAUTION: BEFORE REPLACING A BLOWN MONITOR FUSE, TEST THE PRIMARY INTERLOCK RELAY, SECONDARY INTERLOCK
SWITCHES, DOOR SENSING SWITCH AND MONITOR SWITCHES FOR PROPER OPERATION.
If the monitor fuse is blown by improper switch operation, the monitor fuse and monitor switch must be replaced with "monitor fuse and monitor
switch assembly" part number FFS-BA033WRKZ, even if the monitor switch operates normally. The monitor fuse and monitor switch assembly is
comprised of a 20 ampere fuse and switch.
5. Reconnect all leads removed from components during testing.
6. Reinstall the rear cover and the outer case (cabinet).
7. Reconnect the power supply cord after the rear cover and the outer case are installed.
8. Run the oven and check all functions.
Screw Driver
Latch hook
Monitor switch (2)
Monitor switch (1)
Ohmmeter
7 – 3