Econavi Function - Panasonic CZ-RTC6BLW Operating Instructions Manual

Table of Contents

Advertisement

ECONAVI function

This function is available by attaching an optional ECONAVI sensor.
The ECONAVI sensor detects human activity and conserves energy based on the
activity level.
Overview of the ECONAVI function
High activity
Low activity
No one in the room
• When the sensor
detects movements in
the room which has
been empty, it will
resume operation to
match with the activity
level.
• Cooling: Target temperature is the same as the set temperature.
• Heating: Target temperature is 1 °C lower than the set temperature.
• Cooling: Target temperature is 1 °C higher than the set
temperature.
• Heating: Target temperature is the same as the set temperature.
No one in the room for 20 minutes
• Cooling: Target temperature is 2 °C higher than the set
temperature.
• Heating: Target temperature is 2 °C lower than the set temperature.
No one in the room for 3 hours*
• When no one is in the room for approx. 3 hours* or more, the unit
operates in the specified Absence operation mode.
* This depends on the type of indoor unit.
13