INTELLIGENT EYE operation is useful for energy saving
„ People are detected in the sensing area.
The air conditioner is in normal operation while the
sensor is detecting human movement.
Energy saving operation
• If no presence detected in the room for 20 minutes, the energy saving operation will start.
• This operation changes the temperature by +2°C in COOL / +2°C in DRY operation from the set temperature.
When the room temperature exceeds 30°C, the operation changes the temperature by +1°C in COOL / +1°C in DRY
operation from the set temperature.
• This operation decreases the airflow rate slightly in FAN operation only.
NOTE
Notes on INTELLIGENT EYE operation
• Application range is as follows.
Vertical angle 90°
(Side view)
90°
• When the air conditioner is function in INTELLIGENT EYE operation, if no people are detected in the areas for 20 minutes, the air conditioner
switches to the energy-saving mode with the set temperature shifted by 2°C.
The air conditioner may switch to the energy-saving operation even if there are people in the areas. It may happen depending on the clothes
people are wearing if there are no movements of the people in the areas.
• The sensor may not detect moving objects further than 7m away. (Please see the application range)
• Sensor detection sensitivity changes according to the indoor unit location, the speed of passers-by, temperature range, etc.
• The sensor could also mistakenly detect pets, sunlight, fluttering curtains and light reflected off of mirrors as passers-by.
• NIGHT SET mode
Page 28
Horizontal
angle 110°
55° 55°
(Top view)
will not switch on during use of INTELLIGENT EYE operation.
„ No people are detected in the sensing area.
The air conditioner will switch to energy-saving
mode after 20 minutes.