AUTODOME inteox 7000i - 2MP (in-ceiling)
Figure 10.1: N.O.S. - Normally Open Supervised Connections
1
2
3.
AUTODOME Programmed N.O.S.
Contact
Open
Closed
Cut or break
Configuring a Normally Closed Supervised Alarm
1.
2.
Figure 10.2: N.C.S. - Normally Closed Supervised Connections
1
2
3.
AUTODOME Programmed N.C.S.
Contact
Open
Closed
Short
Bosch Security Systems
2.2K
Dry Contact
Alarm 1 or 2 only (Pin 5 or 6)
From Configuration, select Alarm > Alarm Inputs. For Input 1, enter a Name for the
Alarm input. In the field Active, select N.O.S.. Finally, select an Action. See the table
below for contact and condition details.
Alarm Condition
Normal
Alarm
Tamper
Install a 2.2 K end-of-line resistor in the alarm circuit.
Connect the alarm wires to input 1 or 2 (pin 5 or 6) and to the ground (pin 7) at the
camera.
2.2K
Dry Contact
Alarm 1 or 2 only (Pin 5 or 6)
From Configuration, select Alarm > Alarm Inputs. For Input 1, enter a Name for the
Alarm input. In the field Active, select N.C.S.. Finally, select an Action . See the table
below for contact and condition details.
Alarm Condition
Alarm
Normal
Tamper
Installation Manual
Connection | en
3
Dome Connector
4
Ground (Pin 7)
3
Dome Connector
4
Ground (Pin 7)
29
2021-08 | 1.4 |