6.2 Function Settings

Click the "SIS" program to open the window (as shown below). Click "Exit" to close the
program.
a.
Configure the communication protocol; location, baud rate, COM port, etc. (for details,
see the previous section, Buttons).
b.
To connect to the sensor, click the "Link" button to change it into "Stop" in the
"Production" page. To disconnect from the sensor, click the "Stop" button to change it
into "Link".
c.
When the sensor is connected successfully, real-time data such as the firmware
version, hardware version, product model, and sensitivity of the sensor are showed in
the program.
d.
No data is showed if the sensor does not have the appropriate communication protocol
or the connection is unsuccessful.
e.
The Programmer Box is intended for parameter setting and debugging of the SIS
Sanitary Intelligent Level Switch only and not suitable to be permanently connected as
the control unit of a monitoring system. We cannot guarantee compatibility if it could be
connected to a sensor from other brands.