Maintenance - WilTec XPOtool 63122 Operation Manual

Table of Contents

Advertisement

To remove the inner part, turn its connector in the direction of the arrow marked "LOOSE" and
then pull the connector out of the inlet.
The hoover also offers the possibility to connect a hose to the outlet so that it can also be
used as a blower. The hose is connected to the connector by pressing the socket (IX).
Commissioning
Attention!
Sucking up hot ash is prohibited. The temperature of the suction material must not exceed
40
.
Make sure that all preparatory activities have been carried out.
Likewise, make sure that the hoover switch is set to "O" (Off) (V).
Now insert the plug of the power cord into the mains socket, then set the switch to "I" (On).
After finishing work and before maintenance work, switch the hoover off again at the switch
and pull out the plug.
Notice!
When using the hoover as a blower, make sure that the container has been emptied and the
filter cleaned or replaced with a new one. There is a risk of debris still remaining in the container being
blown out through the outlet opening.

Maintenance

Note!
Pull out the plug before maintenance work!
After each use of the hoover, the container, the lid seal and the air filter must be checked as
described in these instructions.
The ash vacuum cleaner is cleaned from the outside with compressed air of no more than 3
bar pressure. Special attention should be paid to the permeability of the ventilation open-
ings of both the supply and exhaust air. If necessary, clean them with compressed air of no
more than 3 bar. Do not use sharp metal objects to clean the ventilation openings.
Do not immerse the ash vacuum cleaner in water for cleaning.
The hoover hose must be checked for damage before and after use. It is forbidden to use a
damaged hose. Major soiling of the housing should be removed with a soft cloth.
https://www.XPOtool.com