Download Print this page

Intermatic P1131 Owner's Manual page 2

Portable heavy duty pool & spa timer

Advertisement

Congratulations
You have made the right choice in purchasing a Pool and Spa Timer
that provides convenience as well as energy savings and it is designed for
indoor or outdoor use.
SAVE THESE IMPORTANT SAFETY INSTRUCTIONS
WARNING
• Do not permit children to operate the timer or pool/spa unless
they are closely supervised at all times.
• Install only on a GROUNDED 120VAC circuit protected by a
Ground Fault Circuit Interrupter.
• Test GROUND FAULT protection regularly. If it fails to reset, DO
NOT USE the pool or spa! Contact a qualified service technician.
• Always disconnect electricity before servicing this timer or
the equipment connected to it. THIS TIMER IS NOT TO BE
USED AS A POWER DISCONNECT.
• Timer must be installed vertically at least 3 ft. above ground
level and at least 5 Ft. away from edge of pool or Spa.
• Equipment connected to this timer should not exceed capacity
of timer.
• Use timer only for its intended use as described in this manual.
The protective cover should always be in place.
Troubleshooting Guide
Symptom
No power at
timer's receptacle
Timer loses time
Timer's receptacle
is "hot" (energized)
at all times
Risk of Electric Shock
Cause(s)
• No power to timer
• Open GFCI
• Timer contacts open
• Defective timer
• Power to timer is
not continuous
• Defective timer
• No OFF trippers in dial
• Defective timer
Corrective Action
Check circuit breaker in panel.
Reset and test GFCI.
Turn timer to ON, check timer
setting and operation.
Replace timer.
Check branch circuit that
timer is plugged in to.
Replace timer.
Check timer operation.
Replace timer.