Lightolier Atom Lytespan CAM250VA Installation & Operation Manual

Track lighting

Advertisement

Quick Links

Lytespan
®
Track Lighting
Addressable Track Module System
Installation
&
Operations Manual
For Use with Catalog Numbers:
CAM250VA, CAM250ND,
CAMTM, CAMWRC, & CAMLRC

Advertisement

Table of Contents
loading

Summary of Contents for Lightolier Atom Lytespan CAM250VA

  • Page 1 Lytespan ® Track Lighting Addressable Track Module System Installation & Operations Manual For Use with Catalog Numbers: CAM250VA, CAM250ND, CAMTM, CAMWRC, & CAMLRC...
  • Page 2: Table Of Contents

    Wall Remote Control (WRC) - A hard wire unit will interface with ATOM TM & Lightolier Controls Compose Programming Modules ..... . 13 System.
  • Page 3: Addressable Track Non-Dimming On/Off Module (Ndm) - Cam250Nd

    17 modules per circuit (To control more IR & LASER than 17 modules, additional circuits must be used and RECEIVER connected with Lightolier Controls Compose Firewall. (Target area for The Firewall is available in 4 or 8 circuit units.). laser & IR signals)
  • Page 4: Wall Remote Control (Wrc) - Camwrc

    The Wall Remote Control can control up to 17 modules per circuit (To control more than 17 TRACK modules, additional circuits must be used and BEAD connected with Lightolier Controls Compose Firewall. The Firewall is available in 4 or 8 circuit units.). ATTACHMENT MODULE LEVER...
  • Page 5: Atom Laser Remote Control (Lrc)

    • Multiple modules can be programmed at the same 4. ATOM Laser Remote Control (LRC) time by aiming the laser at their Target area for The ATOM Addressable Track Dimming, Non-Dimming Laser & IR signals, thereby selecting them and also On/Off, &...
  • Page 6: Replacing Batteries

    Replacing Batteries 5. First Time Installation & Test First Time Use: Checklist: The LRC comes with a protective plastic between the This section explains a few things you should know for batteries and the contact on the remote to save the proper operation and easier use of the ATOM system.
  • Page 7: Programming Atom (Basic)

    Testing a TM Programming Modules Programming a DM or NDM 1. Turn off power to track. 2. Install modules into track with luminaire attached Creating Scenes with One or Multiple Modules (See Section 3 – Installation of Modules to Lytespan 1.
  • Page 8: Programming A System

    3 If they will be cycling on different circuits using seconds, causing the LED to blink rapidly and then Lightolier Controls Compose Firewall, up to two cycles after 3 seconds stay on. Release the Fade button.
  • Page 9: Programming Atom (Advanced Features)

    (To use default or programmed Fade Rate skip this An example of a Cycle Sequence using all of the above step and advance directly to step 6b). combinations is as follows: Advance to step 6b. Pgm Step I: Fade in 1.5 seconds to Scene "A", then b) Enter the desired Scene by pressing the SCENE delay 7 seconds.
  • Page 10 The module’s LED(s) will blink at a 1/2 second rate If you want to program a, DM or NDM’s address to when in program mode. The LRC’s LED will also match the address of a TM, WRC, or a Compose ™...
  • Page 11: Operation Of The Atom System

    Enabling/Disabling the Verify Command (TM) Turning On & Off (DM, NDM, & TM) Using the LRC: NOTE: This command is only used if using a Lightolier Controls Compose CM Master. ™ NOTE: If using a TM and would like to communicate with all modules (with it’s same address) at once, skip...
  • Page 12 and place it in program mode. (When using multiple Starting a Pre-Programmed Cycle (TM) modules, select them in the same manner if they need Using the LRC: to be programmed identically to the first module.) 1. Press the Cycle button. The module’s LED(s) will blink at a 1/2 second rate 2.
  • Page 13: Factory Defaults

    Scenes are only available when Scene: Level 13% - Fade 3 Sec saving.) using a Lightolier Controls Compose Scene: Level 10% - Fade 3 Sec 2. Press and hold the Begin button for greater than 8 Button Wall Master.
  • Page 14: Appendix

    Setting an address will also • The batteries may need replacement or the Protective allow you to communicate with the Lightolier Controls plastic may need to be removed (first time use only). Compose PLC line.
  • Page 15 DO NOT THROW AWAY! A Genlyte Company 631 Airport Road, Fall River, MA 02720 A Genlyte Company 10911 Petal Street, Dallas, TX 75238 For technical/sales assistance call: 1-800-526-2731 Made in U.S.A. © Lightolier 2001 www.lightolier.com www.lolcontrols.com IS: ATOM...