3.3.5

Handwheel inputs - X10

Pin assignment
Type
Cable
Table 3- 9
Illustration
Connecting
You are allowed to connect at most 2 electronic handwheels at connector X10 on the PPU.
The handwheels must meet the following requirements:
Transmission procedure
Signals
Max. input frequency
Phase shift between Track A to Track
B
Supply
Electrical Installation Manual
Operating Instructions, 12/2014, 6FC5397-2EP10-0BA0
Mini Combicon 10-pin
Max. length: 3m
Pin assignment of X10
Pin
1
2
3
4
5
6
7
8
9
10
3.3 Connecting the interfaces on the PPU
Signal
Comment
A1
TRACK A, handwheel 1
A1_N
NEGATIVE TRACK A, handwheel 1
B1
TRACK B, handwheel 1
B1_N
NEGATIVE TRACK B, handwheel 1
+5V
+5V power output
M
Ground
A2
TRACK A2, handwheel 2
A2_N
NEGATIVE TRACK A2, handwheel 2
B2
TRACK B2, handwheel 2
B2_N
NEGATIVE TRACK B2, handwheel 2
5V square wave signals (TTL level or RS422)
Track A as a true and negative signal (U
Track B as a true and negative signal (U
500 kHz
90
±30
o
o
5V, max. 250 mA
Connecting
U
)
a1
a1
U
)
a2
a2
29