MAINTENANCE

WATER PUMP DRIVE BELT

To tighten the water pump belt:
1. Loosen the nuts which hold the water pump
mount to base.
2. Turn the belt tension adjusting bolt until the
proper belt tension is achieved. (1/2" deflection
in the center of the belt, halfway between the
pulleys).
3. While checking the alignment, tighten the nuts
which hold the water pump mount to base.
WATER PUMP CLUTCH
clutch, make certain that bolt is re-torqued to the
proper value.
Torque Value
Component
Inch pounds
Water pump
shaft bolt

FLOAT VALVE (WATER BOX)

The float valve should only be adjusted if the water
box is overflowing or the water level in the box is
lower than 5-1/2".
1. If the box is overflowing, remove, and check the
float valve for debris or damage.
NOTE: If the float ball has any water inside it
must be replaced.
When replacing float ball, DO NOT over- tighten,
as the rod can puncture the ball. Make sure to
tighten the nuts on the rod.
2. Disassemble the valve and check the piston and
seat for damage, replace if needed. See the
"Illustrated Parts Listing" for a parts break-down.

WASTE TANK STRAINER BASKET

The strainer basket located inside the waste tank
should be removed and cleaned whenever it is full of
debris. This should be done at the end of each job.
4-7
After removing or
replacing water pump
Foot pounds
192
16
EVEREST EFI 980197 06/30/04

Y-STRAINER (OUTLET)

Inspect the Y-strainer after the first week of running
the unit by unscrewing the screen and remove any
accumulated debris. Inspect the strainer again
every 2 weeks.
The Y-strainer should then be inspected every
month. However, if the Y-strainer has a frequent
build-up of debris it should be inspected and cleaned
more often.

TEMPERATURE BALANCE ORIFICE

Inspect the Temperature Balance Orifice every
week. Be sure to drain the water box below ½ full.
Clean as necessary. The orifice needs to be kept
clean. Cleaning in this waw will be dependent on
the water hardness you are using.

CHECK VALVE (OUTLET)

Inspect the check valve when rebuilding the
chemical pump or as needed. Remove and
disassemble the check valve. Check the Teflon seat
for debris or abnormal wear. Clean or replace seat if
needed.
NOTE: Improper seating of the check valve poppet,
damaged spring, or o-rings will cause poor operation
of the chemical system.
For the procedure, see the "General Service
Adjustments" section in this manual for details.

CHEMICAL PUMP

Rebuild the chemical pump every 500 hours. This
involves changing the diaphragm and check valves.
For the procedure, see the "Chemical Pump"
section in this manual for details.
NOTE: Inspect chemical filter daily.