Parameter
Measuring range
Emission factor
Measuring optics
Resolution
Temperature probe
Response time
Temperature units
Display
Accuracy
Automatic switch off
Storage conditions
Power supply
CE-Conformity
Electromagnet conductivity
Dimensions
8
Guarantee
Prerequisite for the fulfilment of guarantee service is that the details of defect should be informed to us immediately and within the stipu-
lated guarantee period. Of course, damages due to unintended use or non-compliance of operating instructions are excluded from this
guarantee coverage. Moreover, defective sensors or sensing units and also calibration service are not covered in the guarantee.
In addition, the guarantee also turns invalid if the device is opened. The serial number on the product should not be changed, damaged
or removed. Apart from the guarantee service, if any essential repairs are required to be carried out, the service is free. However, further
services and also postage and packing expenses are chargeable. Compensation demands on the basis of claim for liability or damages
during the guarantee period are excluded and these are, in general, not legally covered.
9
Repair and calibration services
During the tenure of guarantee period, we are very much at your disposal with our service support. For any malfunctioning, you can simply
send back the product to us with a short description of problems observed. Please don't forget to mention your telephone number to
enable us contact you for any possible queries. We shall inform you about the likely amount of repair charges before taking up the repair
activity. The cost estimate is provided free. The postage and packing charges for return are to be added over and above the repair costs.
In our calibration laboratory, we can also calibrate your measuring and testing devices with repeatability of National standards. Please
contact us, we would be pleased to send you a non-committal offer!
B+B Thermo-Technik GmbH
Heinrich-Hertz-Str. 4,
78166 Donaueschingen
Germany
Technical changes reserved
0141 0316-190 30.11.2021
Specification
-40...1500 °F
-40...816 °C,
Adjustable (0,3...1,0)
12:1
1,0 °C / 1,0 °F at > 300 °C
0,1 °C / 0,1 °F at < 300 °C
Infrared
500 ms
°Celsius, °Fahrenheit
LC-Display, illuminated
±2 °C at < 0 °C
±2 % / 2 °C at 0...+300 °C
±2,5 % at +300...+500 °C
±3 % at > 500 °C
at approx. 10 seconds
-20...50 °C
0...90 % RH
2 x 1,5 V-Battery Mignon AA
2014/30/EU
EN 61326-1:2013
195 x 134 x 50 mm
Tel 0771 83160
Fax 07718316-50
info@bb-sensors.com
www.bb-sensors.com
B+B Thermo-Technik GmbH | Heinrich-Hertz-Straße 4 | D-78166 Donaueschingen
Fon +49 771 83160 | Fax +49 771 8316-50 | info@bb-sensors.com | bb-sensors.com
10 / 12

Advertisement

Table of Contents
loading

This manual is also suitable for:

Shop 0560 8895

Table of Contents