Earth Loop Water Piping; Closed - Econar GeoSource 2000 GV Series Installation And Operating Instructions Manual

Vertical and horizontal forced air
Table of Contents

Advertisement

IV.
EARTH LOOP WATER
PIPING
Since
water is the
source
of
energy
in
the
wintertime
and
the
energy sink
in
the
summertime, good water supply is
possibly
the
most important requirement
of
a
geothermal
heat
pump
system
installation.
There
are
two
common
types
of
water supplies, closed
loop
systems and
open
loop
systems.
A.
Closed
Loop Applications
A
closed
loop
system
recirculates
the
same
water/antifreeze solution through
a
closed
system
of
underground high-density polyethylene
pipe.
As
the
solution
passes
through
the
pipe,
it
collects
heat
(in
the
heathg
mode) that
is
being transferred
from
the
relatively
warm surrounding soil through
the
pipe
and
into
the
relatively
cold
solution.
The solution is circulated to
the
heat
pump,
which
pulls
heat
out
of
the solution,
and
then
back through
the
ground to extract more
heat
from
the
earth.
The GeoSource 2000 is
designed
to
operate on
either
vertical
or horizontal
closed
loop
applications. Vertical
loops
are
typically
installed
with
a
well
drilling
rig
up to
200 feet
deep
or
more. Horizontal
systems are
typically
installed
with
excavating
or
trenching equipment
approximately six to eight feet
deep,
depending
on
geographic
location
and
length
ofpipe
used.
Earth loops
must be
sized
properly for
each
particular
geographic
TO/FROM
CLOSED LOOP
area,
soil type,
and
individual
capacity requirements.
Contact your
local
installer or
ECONAR's
Customer
Support
for loop
sizing requirements
in your
area.
Since
normal
whtertime
operating entering water
temperatures
@Ury)
to
the heat
pump
are
from
25oF
to
32oF,
the solution
in
the
earth loop must
include
antifreeze. GTF
and
propylene
glycol
are
common
antifreeze
solutions. GTF
is
methanol-based
antTfreeze,
which
should
be
mixed
50Vo
with
water to achieve freeze
protection
of
10oF. Propylene
glycol
antifreeze solution
should be
mrxed25Vo
with
water to obtain a
15oF
freeze
protection. DO
NOT
mix
more
than25%o
propylene
glycol with
water
in
an
attempt
to
achieve
a
lower
than
15T
freeze
protection,
since
more concentrated mixtures
ofpropylene glycol
become too viscous
at
low
temperatures and cannot be
pumped through
the
earth
loop.
Insufficient
amounts
of
antifreeze may result
in
a
freeze
rupture
of
the
unit,
and can cause
unit
shutdown
problems during cold weather operation (when
the heat
pump
experiences the
longest run
time)
due
to
loop
temperatures
falling
below
the freeze
protection
of
the
loop
solution.
Flow
rate requirements
for
closed
loops
are
higher than
open
loop
systems because
water temperatures supplied to
the heat
pump
are
generally
lower
(see
Table
3).
Between
2.5 to
3.0
gallons
per
minute
(GPM)
per
ton
are
required
for
proper operation
of
the heat
pump
and the
earth
coupled
heat exchanger.
\
f
\
Figure
1-
Closed
Loop
Water Plumbing
4
.Jl
IN
OUT
PmPPAK
Presre'/
Tmposhre
(P/T)
Pofis
J
il
il
il