Lotus CP-94ETX Installation And Operating Instructions Manual

Lotus CP-94ETX Installation And Operating Instructions Manual

Electric pasta cooker for professional use

Advertisement

Quick Links

Installation and operating instructions
ELECTRIC PASTA COOKER FOR
PROFESSIONAL USE
CP-94ETX CP-98ETX CPA-94ETX CPA-98ETX
Model LIBR.ISTR.CPX 90E CON SIC.
Code 563025602
Review 1
Edition date 15/01/2020
Language English
LOTUS S.p.A.
Via Calmaor, 46
31020 San Vendemiano
+39 0438 778020
+39 0438 778277
Translation of the original instructions

Advertisement

Table of Contents
loading

Summary of Contents for Lotus CP-94ETX

  • Page 1 Installation and operating instructions ELECTRIC PASTA COOKER FOR PROFESSIONAL USE CP-94ETX CP-98ETX CPA-94ETX CPA-98ETX Model LIBR.ISTR.CPX 90E CON SIC. Code 563025602 Review 1 Edition date 15/01/2020 Language English LOTUS S.p.A. Via Calmaor, 46 31020 San Vendemiano +39 0438 778020 +39 0438 778277...
  • Page 2: Table Of Contents

    Contents Contents INTRODUCTION ......................... Installation drawing ........................Components..........................Example installation of the appliance................... GENERAL INFORMATION......................Declaration of compliance......................User information, RAEE Directive on waste electrical and electronic equipment ......Technical data table ........................INSTALLATION........................... Delivery checks ..........................Removing the packaging ......................Mechanical installation .........................
  • Page 3: Introduction

    INTRODUCTION 1 INTRODUCTION Installation drawing FIG. 1 CP…-94..., CP…-98... A Data Plate B Electrical connection D Water connection R 3/4"M E Water drain R 1"M   Translation of the original instructions...
  • Page 4 INTRODUCTION FIG. 2 CPB-98E A Data Plate B Electrical connection D Water connection R 3/4"M E Water drain R 1"M   Translation of the original instructions...
  • Page 5: Components

    INTRODUCTION Components FIG. A 1 Knob 2 White indicator light 3 Green indicator light 4 Water discharge 5 Safety thermostat accessibility 6 Threaded closing cap   Translation of the original instructions...
  • Page 6 INTRODUCTION FIG. B CP... Water filling tap   FIG. C (ROTARY RESISTANCE) 1 O-rings 2 Rotary heating element   Translation of the original instructions...
  • Page 7 INTRODUCTION WIRING DIAGRAM CP-…ETX (A) 1 Switch 2 Power supply terminal board 3 Switching terminal board 4 Heating element 5 White indicator light 6 Green indicator light 7 Safety thermostat Translation of the original instructions...
  • Page 8 INTRODUCTION WIRING DIAGRAM CPA-…ETX (B) 1 Water level control unit 2-3 Switch 4 Bipolar diverter 5 Water solenoid 6 Bipolar switch 7 Power supply terminal board 8 Switching terminal board 9 Heating element 10 Voltage drop resistance 11 Level probe 12 White indicator light 13 Red indicator light 14 Green indicator light...
  • Page 9 INTRODUCTION Wiring diagram reference table MODELS TERMINAL BOARD CP-94ETX CP-98ETX A + A CPA-94ETX CPA-98ETX B + B   Translation of the original instructions...
  • Page 10: Example Installation Of The Appliance

    INTRODUCTION Example installation of the appliance Translation of the original instructions...
  • Page 11: General Information

    GENERAL INFORMATION 2 GENERAL INFORMATION Declaration of compliance The manufacturer declares that the appliances comply with the requirements of the regulation GAR 2016/426 for the gas part and directive 2014/30/EU,2014/35/EU for the electrical part. Installation must be performed in compliance with current regulations, especially with regard to ventilation of the premises and the exhaust gas evacuation system.
  • Page 12: User Information, Raee Directive On Waste Electrical And Electronic Equipment

    GENERAL INFORMATION User information, RAEE Directive on waste electrical and electronic equipment With regard to the regulatory framework of reference of the European Community, we remind the user of the following:   · Used AAE (Electrical and Electronic Equipment) products must be collected separately ·...
  • Page 13: Installation

    INSTALLATION 3 INSTALLATION Delivery checks On delivery, it is important to check the following:   · External conditions of the packaging · The general status of the equipment · The conformity of the model with the information in the technical data plate and the instruction manual ·...
  • Page 14: Water Connection And Drainage

    INSTALLATION Warning Installation operations, any conversion to other types of gas and start-up must only be   performed by qualified personnel, in accordance with current regulations.   Gas systems, electrical connections and premises where the appliances are installed must comply with current regulations in the country of installation;...
  • Page 15 INSTALLATION · It is advisable to connect the appliance to the hot water pipe (max. 60 °C) to reduce heating times; we also recommend installing a shut-off valve up-line of the appliance · The discharge pipe must be connected to a suitable drain in compliance with applicable legislation. It is advisable to connect pipes without bends to avoid bottlenecks or siphon effects.
  • Page 16: Instructions For Use

    INSTRUCTIONS FOR USE 4 INSTRUCTIONS FOR USE General information This appliance must only be used for its expressly intended purpose for cooking or heating food. Any other use is considered improper. The appliance is also intended for industrial use and must only be used by personnel trained for use and aware of the risks that the hot element entails.
  • Page 17: Emptying The Tank

    INSTRUCTIONS FOR USE Turn the knob to position "0". This control stops the power supply completely   Emptying the tank To perform this operation, open the drain tap (lever in vertical position) which can only be reached from the door of the cabinet underneath the appliance  ...
  • Page 18: Characteristics Of The Feed Water

    INSTRUCTIONS FOR USE Caution If the probe does not detect water in the tank for more than 15 sec., the system disables the   heating element: an alarm is signalled by the red indicator light flashing. When the probe detect water again, the heating element is activated and the red indicator light switches OFF.  ...
  • Page 19: Maintenance

    MAINTENANCE 5 MAINTENANCE Routine When using the appliance over time, it is essential to perform regular maintenance to ensure safe operation. We therefore recommend stipulating a service contract.   Caution Maintenance must only be performed by specialist personnel in compliance with current  ...
  • Page 20: Spare Parts

    MAINTENANCE Spare parts It is possible to replace parts such as the valve, the piezoelectric or the ignition control unit (depending on the type of appliance) or the gas pipes easily and quickly. To replace such parts, proceed as follows:  ...
  • Page 21: Cleaning

    CLEANING 6 CLEANING Routine cleaning Caution The use of flammable fluids to clean the appliance is forbidden     To ensure hygiene and the durability of the appliance, perform external cleaning on a regular basis, taking care not to damage the cables and the electrical connections. Before starting cleaning, disconnect the appliance from the power supply.

This manual is also suitable for:

Cp-98etxCpa-94etxCpa-98etx

Table of Contents