Lotus CP-558G Installation And Operating Instructions Manual

Gas pasta cooker for professional use

Advertisement

Quick Links

Installation and operating instructions
GAS PASTA COOKER FOR
PROFESSIONAL USE
CP-558G CPA-558G
Model LIBR.ISTR.CP110G
Code 5630516A0
Review 1
Edition date 08/06/2022
Language English
LOTUS S.p.A.
Via Calmaor, 46
31020 San Vendemiano
+39 0438 778020
+39 0438 778277
Translation of the original instructions

Advertisement

Table of Contents
loading

Summary of Contents for Lotus CP-558G

  • Page 1 Installation and operating instructions GAS PASTA COOKER FOR PROFESSIONAL USE CP-558G CPA-558G Model LIBR.ISTR.CP110G Code 5630516A0 Review 1 Edition date 08/06/2022 Language English LOTUS S.p.A. Via Calmaor, 46 31020 San Vendemiano +39 0438 778020 +39 0438 778277 Translation of the original instructions...
  • Page 2: Table Of Contents

    Contents Contents INTRODUCTION ......................... Installation drawing ........................Components..........................Example installation of the appliance................... GENERAL INFORMATION......................Declaration of compliance......................User information, RAEE Directive on waste electrical and electronic equipment ......Technical data table ........................INSTALLATION........................... Delivery checks ..........................Removing the packaging ......................Mechanical installation .........................
  • Page 3: Introduction

    INTRODUCTION 1 INTRODUCTION Installation drawing FIG. 1 CP-558G, CPA-558G A Data Plate B Electrical connection C Gas connection D Water connection R 3/4"M E Water drain R 1"M Translation of the original instructions...
  • Page 4: Components

    INTRODUCTION Components FIG. C 1 By-pass   FIG. B CP... Water filling tap   FIG.D 1 Bracket 2 Pilot light nozzle 3 Ignition spark plug 4 Extends drainage 5 Injector Translation of the original instructions...
  • Page 5 INTRODUCTION WIRING DIAGRAM CP-558G 1 Ignition spark plug 2 Burner ignition control unit 3 Water level control unit 4 Gas solenoid 5 Power button 6 Bipolar switch 7 Power supply terminal board 8 Level probe 9 Red warning light Translation of the original instructions...
  • Page 6 INTRODUCTION WIRING DIAGRAM CPA-558G 1 Ignition spark plug 2 Burner ignition control unit 3 Water level control unit 4 Bipolar diverter 5 Water solenoid 6 Gas solenoid 7 Bipolar switch 8 Illuminated bipolar switch 9 Power supply terminal board 10 Level probe 11 Red indicator light Translation of the original instructions...
  • Page 7: Example Installation Of The Appliance

    INTRODUCTION Example installation of the appliance Translation of the original instructions...
  • Page 8: General Information

    GENERAL INFORMATION 2 GENERAL INFORMATION Declaration of compliance The manufacturer declares that the appliances comply with the requirements of the regulation GAR 2016/426 for the gas part and directive 2014/30/EU,2014/35/EU for the electrical part. Installation must be performed in compliance with current regulations, especially with regard to ventilation of the premises and the exhaust gas evacuation system.
  • Page 9: User Information, Raee Directive On Waste Electrical And Electronic Equipment

    Electrical technical data table CP S110G MAXIMUM MAXIMUM POWER SUPPLY MODEL POWER SUPPLY ABSORPTION ELECTRIC CABLE POWER (kW) silicon type CP-558G 230V~ 50/60 Hz 0,02 3 x 1 mm² CPA-558G 230V~ 50/60 Hz 0,16 0,035 3 x 1 mm²   Technical data table CP S110G...
  • Page 10: Installation

    INSTALLATION 3 INSTALLATION Delivery checks On delivery, it is important to check the following:   · External conditions of the packaging · The general status of the equipment · The conformity of the model with the information in the technical data plate and the instruction manual ·...
  • Page 11 INSTALLATION Warning Installation operations, any conversion to other types of gas and start-up must only be   performed by qualified personnel, in accordance with current regulations.   Gas systems, electrical connections and premises where the appliances are installed must comply with current regulations in the country of installation;...
  • Page 12 INSTALLATION valve and fast-closing valve. Once installation is complete, make sure that there are no gas leaks from the fittings; to do this, do not use a naked flame but substances that do not cause corrosion, such as solutions of soapy water or leak detectors.
  • Page 13 INSTALLATION - "A" type devices (see data plate)   "A" type appliances must discharge combustion products into appropriate hoods, or similar devices, connected to an efficient fume stack or directly to the outside. (Natural evacuation) Fig. 1 If this is not possible, using an air suction device connected directly to the outside is permitted (Forced Evacuation) Fig.2, having a flow capacity not lower than the value defined in point 4.3 of the UNI-CIG 8723 standard.
  • Page 14: Water Connection And Drainage

    INSTALLATION 1 Windproof fume stack (fig.3) - Extractor hood (fig.4) 2 Servo system   "B11" type appliances are supplied on request with a hood or a hood and windproof fume stack to be assembled and delivered separately. Water connection and drainage ·...
  • Page 15: Burners Technical Data Table (Itgb)

    BURNERS TECHNICAL DATA TABLE (ITGB) 4 BURNERS TECHNICAL DATA TABLE (ITGB) Burners technical data table Technical data table - Burner CP S110G 12.68 kWh/KG 12.87 kWh/KG 9.45 kWh/m3st.   BUTANE PROPANE METHANE H 30 mbar 37 mbar 20 mbar CP..-558G  ...
  • Page 16: Instructions For Use

    INSTRUCTIONS FOR USE 6 INSTRUCTIONS FOR USE General information This appliance must only be used for its expressly intended purpose for cooking or heating food. Any other use is considered improper. The appliance is also intended for industrial use and must only be used by personnel trained for use and aware of the risks that the hot element entails.
  • Page 17: Starting The Main Burner And Adjusting The Temperature

    INSTRUCTIONS FOR USE Starting the main burner and adjusting the temperature · Turn the knob into position to set the burner to maximum · Turn the knob into position to set the burner to minimum Switching the main burner off ·...
  • Page 18: Characteristics Of The Feed Water

    INSTRUCTIONS FOR USE The "level button" defines the level of water in the tank: high level for cooking pasta, low level for steaming   Warning Keep the level sensor clean     Caution If the probe does not detect water in the tank for more than 15 sec., the system disables the  ...
  • Page 19: Maintenance

    MAINTENANCE 7 MAINTENANCE Routine When using the appliance over time, it is essential to perform regular maintenance to ensure safe operation. We therefore recommend stipulating a service contract.   Caution Maintenance must only be performed by specialist personnel in compliance with current  ...
  • Page 20: Minimum Setting

    MAINTENANCE Warning After conversion to another type of gas, update the technical data plate to indicate the type of   gas for which the appliance has been converted. Minimum setting · After conversion to use another type of gas, or if a flame is too high when the knob is in position small flame), adjust the minimum setting by turning the by-pass screw.
  • Page 21: Cleaning

    CLEANING 8 CLEANING Routine cleaning Caution The use of flammable fluids to clean the appliance is forbidden     To ensure hygiene and the durability of the appliance, perform external cleaning on a regular basis, taking care not to damage the cables and the electrical connections. Before starting cleaning, disconnect the appliance from the power supply.

This manual is also suitable for:

Cpa-558g