NL Troubleshooting
Malfunction
E:32-00 lights up alternately
or the water supply indicator
lights up.
E:92-40 lights up alternately.
E:61-03 lights up alternately.
The water is not pumped
out.
E:61-02 lights up alternately.
42
Cause
The sieves in the water connection
inlet or AquaStop
hose are clogged.
Strainers are dirty or clogged.
Drain hose is clogged or
kinked.
Siphon connection is still closed.
Drain pump cover is
loose.
Drain pump is blocked.
Drain pump cover is
loose
Troubleshooting
Switch off the device.
1.
Remove the plug from the socket.
2.
Turn off the tap.
3.
Unscrew the water connection.
4.
Remove the strainer from the inlet hose
5.
Clean the strainer.
6.
Place the strainer in the supply hose.
7.
Screw on the water connection.
8.
Check the water connection for
9.
leaks.
Put the plug back in the
10.
socket.
Switch on the device.
11.
Clean the sieves.
"Cleaning Sieves", Page 38
Route the drain hose without
1.
kinks.
Remove the remains.
2.
Check the connection to the
fon and open it if necessary.
Remove the cover of the "drain
pump" → Page 54 well fixed.
Clean the drain pump.
"Clean the drain pump",
Page 54
Remove the cover of the "drain
pump" → Page 54 well fixed.