Too many RS-485 termination resistors (120ohm) on the same RS-485 communication bus. Only the
last light on the bus should have the termination resistor in use.
Check Modbus data wiring.
Light does not change modes between day, twilight and night
Check that the photocell has an uninterrupted view of the sky.
Check that there are no external light sources that interfere with the photocell.
Photocell is sampled once in a minute and read values are averaged to avoid sudden state changes.
Unless test mode is enabled, it takes approx. three (3) minutes to change system state between day,
twilight and night.
Light does not flash in sync
GPS antenna is mounted on top of obstruction light's PCB under the glass cover. Antenna needs a
non-blocked view to GPS satellites in orbit. After start-up, GPS receiver may take up to 30 mins to
obtain correct time data from GPS satellites. This operation requires data from several GPS
satellites.

4.11 Spare parts

Part code
SP-MICMP-CTRL
SP-MICMP-PSUAC
SP-MICMP-PSUDC12
SP-MICMP-PSUDC24
SP-MICMP-GC
© Obelux Oy 2020
Description
Replacement main control board
Replacement power supply unit (100-240 VAC)
Replacement power supply unit (10-20 VDC)
Replacement power supply unit (20-60 VDC)
Replacement glass cover including gaskets