4.1 ICAO models

4.1.1 ICAO Stand-alone mode (basic model)

Flashing mode is selected with DIPs 1-3.
DIP switch
1
2
3
off
off
off
on
off
off
off
on
off
on
on
off
off
off
on
on
off
on
off
on
on
on
on
on
Flashing rate is selected with DIPs 4-5. Steady modes don't flash. A steady mode can be selected with DIPs
1-3.
DIP switch
4
5
off
off
20
on
off
30
off
on
40 *
on
on
60
Photocell operation is configured with DIP6. When photocell controls the light, the light will change its
flashing mode based on ambient luminosity.
DIP switch
6
off
Photocell is disabled *
on
Photocell controls the light
Turn DIP7 on for correct operation.
DIP switch
7
off
This device is slave *
on
This device is master (must be on)
Turn DIP8 off for correct operation.
DIP switch
8
off
Stand-alone (must be off) *
on
Modbus
* Factory default
© Obelux Oy 2020
2,000cd red, ICAO (flashing, check DIPs 4-5)
2,000cd red and infrared, ICAO (flashing, check DIPs 4-5) *
2,000cd red (steady)
2,000cd red and infrared (steady)
200cd red and infrared, ICAO (flashing, check DIPs 4-5)
200cd red and infrared (steady)
Reserved
Reserved
Medium-Intensity 2000cd compact series manual
Flashing mode
Night
Flash rate (FPM)
Photocell mode
Master/Slave mode
Operating mode
Technical information in this document is subject to change without notice.