Test Mode - OBELUX Medium-Intensity 2000cd compact Series Manual

Table of Contents

Advertisement

DIP switch
1
2
3
4
on
off
off
off
off
on
off
off
on
on
off
off
off
off
on
off
on
off
on
off
off
on
on
off
on
on
on
off
off
off
off
on
on
off
off
on
off
on
off
on
on
on
off
on
off
off
on
on
on
off
on
on
off
on
on
on
on
on
on
on
RS-485 bus should be terminated with on-board 120 ohm resistors by turning on the termination DIP switch
on both ends of the communications bus.

4.4 Test mode

To enter test mode, set DIP7 and DIP8 on and all other DIPs off. The light will enter test mode when power
is turned on. To leave the test mode, turn off DIP7 and DIP8 and turn off the power.
DIP switch
7
8
on
on
Test mode enabled. All other DIPs off.
off
off
Test mode disabled.
Light mode is selected with DIPs 1-2. There is normally a delay when changing time-of-day modes (day,
twilight and night) based on photocell data. Using accelerated photocell mode will decrease the delay to a
minimum.
DIP switch
1
2
off
off
Accelerated photocell light behavior
on
off
RED light only
off
on
IR light only
on
on
Reserved
Flashing rate is selected with DIPs 4-5.
DIP switch
4
5
off
off
Steady
on
off
20
off
on
40
on
on
60
© Obelux Oy 2020
Modbus Address
Address 01
Address 02
Address 03
Address 04
Address 05
Address 06
Address 07
Address 08
Address 09
Address 10
Address 11
Address 12
Address 13
Address 14
Address 15
Medium-Intensity 2000cd compact series manual
Test mode
Light mode
Flash rate (FPM)
Technical information in this document is subject to change without notice.
Page 18 of 21