Faa Stand-Alone Mode; Modbus Mode - OBELUX Medium-Intensity 2000cd compact Series Manual

Table of Contents

Advertisement

4.2.2 FAA Stand-alone mode

DIP switch
1
2
3
off
off
off
on
off
off
off
on
off
on
on
off
off
off
on
on
off
on
off
on
on
on
on
on
DIP switch
4
5
off
off
20
on
off
30 *
off
on
40
on
on
60
DIP switch
6
off
Photocell is disabled *
on
Photocell controls the light
DIP switch
7
off
This device is slave *
on
This device is master
DIP switch
8
off
Stand-alone *
on
Modbus
* Factory default

4.3 Modbus mode

The light is in Modbus mode when DIP8 is on. Light is being controlled with an Obelux controller.
DIP switch
8
off
Stand-alone
on
Modbus
Configuration DIP switches 1-4 are used to give the light a RS-485 bus address. Duplicate addresses on the
same bus are not allowed. Give lights connected to the same communication bus an address starting from
address one.
© Obelux Oy 2020
2,000cd red and infrared (flashing) *
2,000cd red (flashing)
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Medium-Intensity 2000cd compact series manual
Flashing mode
Night
Flash rate (FPM)
Photocell mode
Master/Slave mode
Operating mode
Operating mode
Technical information in this document is subject to change without notice.
Page 17 of 21