Icao Stand-Alone Mode - OBELUX Medium-Intensity 2000cd compact Series Manual

Table of Contents

Advertisement

4.1.2 ICAO Stand-alone mode

Flashing mode is selected with DIPs 1-3.
DIP switch
1
2
3
off
off
off
on
off
off
off
on
off
on
on
off
off
off
on
on
off
on
off
on
on
on
on
on
Flashing rate is selected with DIPs 4-5.
DIP switch
4
5
20
off
off
on
off
30
off
on
40 *
on
on
60
Photocell operation is configured with DIP6.
DIP switch
6
off
Photocell is disabled *
on
Photocell controls the light
DIP switch
7
off
This device is slave *
on
This device is master
DIP switch
8
Stand-alone *
off
on
Modbus
* Factory default
© Obelux Oy 2020
2,000cd red, ICAO (flashing, check DIPs 4-5)
2,000cd red and infrared, ICAO (flashing, check DIPs 4-5) *
2,000cd red (steady)
2,000cd red and infrared (steady)
200cd red and infrared, ICAO (flashing, check DIPs 4-5)
200cd red and infrared (steady)
Reserved
Reserved
Medium-Intensity 2000cd compact series manual
Flashing mode
Night
Flash rate (FPM)
Photocell mode
Master/Slave mode
Operating mode
Technical information in this document is subject to change without notice.