Download Print this page

System - Mitsubishi Electric PAC-IF013B-E Manual

Hide thumbs Also See for PAC-IF013B-E:

Advertisement

1

System

Using function
Step
No.
by Modbus
mode
1
Writing
Manual
and
*1
Reading
(Input and
monitoring)
2
3
4
5
Auto *2
Only Reading
6
Manual
(Only monitoring)
7
Auto
*1. Manual step mode by Modbus:
• AHU local controller can send " capacity steps" and "operation mode" by Modbus communication to the interface unit.
• Do NOT send " temperature set point" or "Drive ON/ OFF".
• DIP SW 1-1 to 1-3, and SW6 are as follows. Regarding other settings, refer to the section 2 and the installation manual.
Input type
Modbus
*2. Auto step mode by Modbus:
• AHU local controller can send " Drive ON/ OFF", "operation mode", and "temperature set point" by Modbus communication to the interface unit.
• Do NOT send " capacity request".
• DIP SW 1-1 to 1-3, and SW6 are as follows. Regarding other settings, refer to the section 2 and the installation manual.
Input type
No input (Auto step mode)
*3. Regarding thermistor positions, refer to the installation manual.
*4. Intelligent multiple outdoor unit control by Modbus:
• Input "capacity steps" signal and "operation mode" signal to the main interface unit (which connects to the ref. address 0 outdoor unit)
• Monitoring operation status of all interfaces is available. In this case, connecting to all interface units with Modbus cable is needed.
• Setting DIP SW3-6 to SW3-8, and SW4 of sub interfaces is necessary when monitering sub interfaces.
• Regarding intelligent multiple outdoor unit control, refer to the installation manual.
*5. It is recommended to select Intelligent multiple outdoor unit control.
Design local AHU controller to make sure the following points.
• Minimum capacity request should be 20% or more of total capacity.
• Operate all outdoor units when outdoor temperature is below -15 °C.
2
Input
Number of
type
outdoor unit
outdoor unit control
Modbus
1
2-6
No input
1-5
(Auto step
mode)
"Analog" or
1-6
"Remote switch"
No input
1-5
(Auto step mode)
SW1-1
SW1-2
ON
ON
SW1-1
OFF
Intelligent multiple
N/A
AHU local
controller
Apply *4
■When not monitoring sub interfaces
AHU local
controller
■When monitoring sub interfaces
(Wiring among interface units with Modbus cable)
AHU local
controller
Not apply *5
Input all interfaces separately.
AHU local
controller
N/A
AHU local
controller
Refer to the installation manual.
SW1-3
ON
SW1-2
SW1-3
ON
ON
System *3
Outdoor
Interface
unit
Remote
controller
Interface
Outdoor unit
(Main)
(Ref. adress: 0)
Interface
Outdoor unit
(Sub)
(Ref. adress: 1)
Interface
Outdoor unit
(Sub)
(Ref. adress: 2)
Remote
controller
Interface
Outdoor unit
(Main)
(Ref. adress: 0)
Interface
Outdoor unit
(Sub)
(Ref. adress: 1)
Interface
Outdoor unit
(Sub)
(Ref. adress: 2)
Remote
controller
Outdoor
Interface
unit
Remote controller
Outdoor
Interface
unit
Remote controller
Outdoor
Interface
unit
Remote controller
Outdoor
Interface
unit
Remote
controller
SW6-1
SW6-2
OFF
OFF
SW6-1
SW6-2
OFF
OFF