Download Print this page
Mitsubishi Electric PAC-IF011B-E Installation Manual

Mitsubishi Electric PAC-IF011B-E Installation Manual

Interface (cased)
Hide thumbs Also See for PAC-IF011B-E:

Advertisement

Quick Links

Interface (Cased)
PAC-IF011B-E

INSTALLATION MANUAL

For safe and correct use, read this manual and the outdoor unit installation manual thoroughly before installing
the interface unit.
INSTALLATIONSHANDBUCH
Lesen Sie zum sicheren und korrekten Gebrauch vor Installation der Anlage diese Anleitung sorgfältig durch.
MANUEL D'INSTALLATION
Pour une utilisation sûre et adaptée, lisez attentivement ce manuel avant d'installer l'unité d'interface.
INSTALLATIEHANDLEIDING
Lees deze handleiding grondig door voordat u het interface-apparaat installeert. Dan bent u verzekerd van een
veilig en correct gebruik.
MANUAL DE INSTALACIÓN
Para una utilización segura y correcta del producto, lea este manual detenidamente antes de instalar la unidad
de interfaz.
MANUALE DI INSTALLAZIONE
Per la sicurezza e il corretto utilizzo, leggere attentamente il presente manuale prima di installare l'unità interna.
εΓΧεΙΡΙΔΙΟ ΟΔΗΓΙΩΝ εΓΚΑΤΑΣΤΑΣΗΣ
Για ασφαλή και σωστή χρήση, διαβάστε καλά αυτό το εγχειρίδιο πριν την εγκατάσταση της μονάδας
διασύνδεσης.
MANUAL DE INSTALAÇÃO
Para uma utilização segura e correcta, leia este manual na íntegra antes de instalar a unidade de interface.
INSTALLATIONSMANUAL
Læs af sikkerhedshensyn denne vejledning grundigt, før De monterer interfaceenheden.
INSTALLATIONSMANUAL
För säker och korrekt användning bör du nogrannt läsa igenom denna handbok innan du installerar
gränssnittsenheten.
MONTAJ ELKİTABI
Güvenli ve doğru kullanım için arabirim ünitesini monte etmeden önce bu kılavuzu dikkatli bir şekilde okuyun.
РУКОВОДСТВО ПО УСТАНОВКЕ
Для безопасного и правильного использования перед установкой интерфейсного блока внимательно
прочитайте данное руководство.
FOR INSTALLER
FÜR INSTALLATEURE
POUR L'INSTALLATEUR
VOOR DE INSTALLATEUR
PARA EL INSTALADOR
PER L'INSTALLATORE
ΓΙΑ ΑΥΤΟΝ ΠΟΥ ΚΑΝεΙ ΤΗΝ εΓΚΑΤΑΣΤΑΣΗ
PARA O INSTALADOR
TIL INSTALLATØREN
FÖR INSTALLATÖREN
MONTÖR İÇİN
ДЛЯ УСТАНОВИТЕЛЯ
English
Deutsch
Français
Nederlands
Español
Italiano
ελληνικά
Português
Dansk
Svenska
Türkçe
Русский

Advertisement

loading

Summary of Contents for Mitsubishi Electric PAC-IF011B-E

  • Page 1: Installation Manual

    Interface (Cased) PAC-IF011B-E INSTALLATION MANUAL FOR INSTALLER English For safe and correct use, read this manual and the outdoor unit installation manual thoroughly before installing the interface unit. INSTALLATIONSHANDBUCH FÜR INSTALLATEURE Deutsch Lesen Sie zum sicheren und korrekten Gebrauch vor Installation der Anlage diese Anleitung sorgfältig durch.
  • Page 2 This symbol mark is according to the directive 2002/96/EC Article 10 Information for users and Annex IV. WEEE) Your MITSUBISHI ELECTRIC product is designed and manufactured with high quality materials and components which can be recycled and reused. This symbol means that electrical and electronic equipment, at their end-of-life, should be disposed of separately from your household waste.
  • Page 3: Safety Precautions

    1. Safety precautions 1.4. Before starting the test run • Before starting operation, check that all protective parts are correctly in- Caution: stalled. Make sure not to get injured by touching high voltage parts. • Turn on the main power switch of the outdoor unit more than 12 hours •...
  • Page 4: Electrical Work

    Wiring circuit breaker or isolating switch Outdoor unit Interface unit/outdoor unit connecting cables Interface unit Photo.3-2 Interface unit model PAC-IF011B-E Interface unit-Outdoor unit 3× 1.5 (polar) 1 × Min.1.5 Interface unit-Outdoor unit earth Interface unit-Outdoor unit S1-S2 AC 230 V...
  • Page 5 (SW8) unit power supplies only) Set the SW8-3 to ON. CNS2 Photo.3-3 Interface unit model PAC-IF011B-E Interface unit power supply ~/N (Single Phase), 50 Hz, 230 V Interface unit input capacity 16 A Main switch (Breaker) Interface unit power supply 2 ×...
  • Page 6 3. Electrical work 3.1.4. Connecting external input Demand control is available by external input. It is possible to set the outdoor unit’s power consumption by setting the switch of the interface controller. Switch1, Switch 6 : Input selection of inverter capacity setting Input SW 1-1 SW 1-2 SW 1-3 SW 6-1 SW 6-2 Step for capacity setting...
  • Page 7 3. Electrical work 3.1.5. Connecting External Output The signal in the following states can be output. TB141 Item (OUT1) Operation Output (OUT2) Error Output Normal Error (OUT3) Comp. Output OFF(Comp. OFF) ON (Comp. ON) (OUT4) Defrost Output (Defrosting) 9-10 (OUT5) Mode(Cool) Output (Cooling) 11-12...
  • Page 8: Guide To Plan Local Applications

    Guide to plan local applications * This interface is to connect Mr. Slim inverter outdoor unit of MITSUBISHI ELECTRIC to local applications. Be sure to check the following when planning local applications. * MITSUBISHI ELECTRIC does not take any responsibility on the local system design.
  • Page 9 This product is designed and intended for use in the residential, commercial and light-industrial environment. • Low Voltage Directive 2006/95/EC The product at hand is • Electromagnetic Compatibility Directive based on the following 2004/108/EC EU regulations: Please be sure to put the contact address/telephone number on this manual before handing it to the customer.