ELECTRICAL
Input
Input voltage (DC)
Input current
HV Output
Output polarity
Maximum output voltage (V
Nominal output power
(complete discharge modifications, can be
achieved in regime 0-100% of V
input voltage, 25 °C)
Nominal output power
(partial discharge modifications, can be
achieved in regime 70-100% of V
rated input voltage, 25 °C)
Output power deratings
Voltage stability
Voltage ripple/hysteresis
Efficiency
Protections
Environment
Operation temperature
Storage temperature
Humidity
PBZ-300
<20 A
Positive by default (negative polarity, floating
and bipolar outputs are available on request)
300V, 500V, 700V, 1000V, 2000V, 4000V
)
MAX
or other (user selectable in 300V-4000V range)
300 J/s
, rated
MAX
400 W
,
MAX
Output power is derated when:
-
operating voltage is lower than 70% of V
modifications)
-
operating voltage is lower than V
modifications)
-
ambient temperature is higher than 25 °C
-
input voltage is below minimum rated voltage
24 V
<0.5%
<0.5%
More than 85%
From overheating
+10...+40 °C
-20...+60 °C
90%, non-condensing
PBZ-500
48 V
<18 A
500 J/s
700 W
(PD
MAX
(CD
MAX