HV OUTPUT: 2-pin or 3-pin proprietary connector by OEM Tech
By default PBZ-300 (PBZ-500) is supplied with positive output polarity (P).
Negative output (N), floating output (F) and bipolar output (B) are available on request.
Pin layouts in dependence on modification are given in the table below:
PIN (color)
Number of
Pins
HV– (blue)
GND (black)
HV+ (red)

MOUNTING AND GROUNDING:

Power supply is to be mounted with 4pcs M4 screws (M4x10 or shorter).
By default all grounds of PBZ-300 (PBZ-500)
(HV OUTPUT ground, 24V DC or 48V DC return and Interface return)
are interconnected inside the power supply and connected to the module's chassis.
Other grounding policies are possible on request.
Warning! Power supply enclosure is to be
protectively grounded using provided M4 grounding thread.
COOLING:
Module is forced-air cooled with the built-in fans. No additional cooling is required.
P
N
2
-
-V
GND
GND
+V
-
Grounding policy
Modification
F
HV Negative
-
HV Positive
"V" is output voltage amplitude
B
3
-V/2
GND
+V/2