Download Print this page

OEM PBZ-300 User Manual page 3

Capacitor charging power supplies

Advertisement

Connectors, pins, interface signals
INTERFACE: 13 pin mixed D-SUB connector of 13W3 type
24V DC (48V DC) power and all the control signals are to be connected here.
PIN (color)
A1 (yellow/green)
A2 (red)
A3 (black)
1, 2 (transparent)
3 (orange)
4 (blue)
5 (green)
6 (violet)
7 (blue/white)
8 (white)
9, 10 (black)
Warning! Because of safety reasons we highly recommend to use low voltage
power supply with DC output galvanically insulated from AC input (insulation strength
4000VAC, 2500VAC or 1500VAC is selected in dependence on your application).
DESIGNATION
Module can be protectively grounded via
GND
this pin
24V DC (48V DC)
DC power supply should be connected here
DC RETURN
N/C
-
DC voltage applied between pins 3 and 4
sets up the output high voltage level
HV Program
Calibration is linear, 10V between pins 3
and 4 corresponds to V
Return of HV Program signal
HV Program
In order to improve high voltage stability
HV Program Return isn't connected to the
Return
common ground of Interface
-
N/C
5V TTL if fault occurred, 0V elsewise.
Fault
Fault state is set in the case of overheating.
Pin 7 should be pulled to the ground to
enable the output. Output is disabled while
TTL high level is applied to pin 7 or pin 7 is
left unconnected
Enable
To use power supply in stand-alone regime,
pin 7 can be short-circuited with one of
Interface return pins (e.g. pin 10)
Output voltage monitor
HV Monitor
Calibration is linear, 10V on pin 8
corresponds to V
Return of all Interface signals (Enable, HV
GND
Monitor, Fault) except HV Program
(Interface return)
DESCRIPTION
at the output
MAX
at the output
MAX

Advertisement